This H-bridge controller measures numerous types of input signals as well as provides different outputs. It has three Universal Inputs. The two outputs can provide up to 2.5 A of current. Each output is a half-bridge. They form a full H-bridge when used together. Flexible circuit design gives the user a wide range of configurable input and output types. Powerful control algorithms allow the user to program the controller for a wide range of applications without the need for custom firmware. It features auto-baud-rate detection.
Unit of Measure
Order Code |
N/A P/N: AX103000 |
Operating Voltage |
N/A 12 or 24 VDC Nominal (8…36VDC) |
Inputs |
N/A
Three (3) universal inputs are user selectable as: Voltage, PWM, Frequency, or Digital types. |
Outputs |
N/A
Two (2) outputs are user selectable as: Proportional Voltage, Proportional Current, Hotshot Digital, PWM, High Frequency Drive, or On/Off Digital types The ouputs can also be confiured as 1 H-Bridge or 2 individual High-Side/Low-Side outputs |
Communications |
N/A 1 CAN port (SAE J1939, Auto Baud Rate Detection) |
Control Logic |
N/A Electronic Assistant, P/N: AX070502 |
Enclosure |
N/A
Molded Enclosure, integral connector Nylon 6/6, 30% glass, Laser Welded 4.28 in x 3.69 in x 1.41 in (108.6 mm x 94 mm x 36 mm) Note: L x W x H includes the integral connector Flammability rating: UL 94 HB |
Connections |
N/A Integral 12-pin receptacle (equivalent to TE Deutsch P/N: DTM04-12P) |
Operating Temperature |
N/A -40 to 85 ºC-40 to 185 ºF |
Reference Voltage |
N/A 1 +5V or +8V, ±2%, 100 mA |
Applications |
N/A
Machine control systems for actuators, valves and DC motors. |
Datasheet |
N/A
AX103000 Datasheet |
User Manual |
N/A
AX103000 User Manual |
2D Drawing |
N/A
AX103000-MD-R2 |
STEP Files (3D) |
N/A
12-Pin Laser Welded Assembly |
Compliance |
N/A
LVD - DoC - All RoHS - DoC - All |
Accessories |
N/A
AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions) PL-DTM06-12SA, Mating Plug KIT (1-12 Socket) |