The Tilt Sensor indicates an out of level condition from its mounting location and drives external valves, solenoids, relays, lamps or annunciators for an equipment shut down control or warning system. LED’s provide power and out of level status indicators. It is networked over CANopen®.
Unit of Measure
Order Code |
N/A P/N: AX060150 |
Operating Voltage |
N/A 9 to 32 VDC Power Supply Range |
Communications |
N/A CANopen® |
Enclosure |
N/A
Encapsulated in stainless steel box 108.22 x 42.04x 62.64 mm 4.26 x 1.655 x 2.46 inches (W x H x D) |
Connections |
N/A
6-pin TE Deutsch connector P/N: DT15-6P Mates with TE Deutsch plug P/N: DT06-6S (including W6S wedgelock and sockets) |
Protection Rating |
N/A IP67 |
Operating Temperature |
N/A -40 to 85 ºC-40 to 185 ºF |
Outputs |
N/A
Digital on/off output – up to 2 Amps User selectable: Proportional Current or PWM up to 2A (on request) Short circuit protected. |
Applications |
N/A
Rugged out-of-level indicator and shut down control for mobile equipment including: |
Measurement Range |
N/A
X, Y Axes Specify Angle Between 0.5 to 90° Default Settings: +5°, -5° |
Datasheet |
N/A
AX060150 Datasheet |
User Manual |
N/A
AX060150 User Manual |
2D Drawing |
N/A
AX060150-2D |
Compliance |
N/A
LVD - DoC - All RoHS - DoC - All |
Accessories |
N/A
AX070139, M12 Mating Plug with 2m Cable, Unterminated |