Items |
/Asset/AX030310.jpg AX030310 18 Digital Signal Inputs, CAN Controller, SAEJ1939 |
/Asset/AX030311.gif AX030311 18 Digital Signal Inputs, CAN Controller, CANopen |
/Asset/AX030320.jpg AX030320 18 Digital Signal Inputs, CAN Controller, SAE J1939, 54 CAN Transmit Messages |
|||
Description |
N/A
The 18 Digital Signal Input Module accepts up to 10 digital type inputs (active high/active low, PWM signal, Frequency or counter). Eight additional digital inputs are user selectable as Active High or Active Low. The electroni control can be connected to a variety of machine switches, sensors, PWM signals, etc. It interfaces with the machine’s CAN network (SAE J1939). Standard embedded software is provided. Rugged packaging in addition to a wide-ranging power supply input section for 12V or 24Vdc power suits applications in the harsh environment of mobile equipment with on-board battery power. All setpoints are user configurable using the Electronic Assistant. |
N/A
The 10 Universal Signal Inputs Controller accepts up to 10 analog or digital type inputs (0-5V, 0-10V, 0-20 mA, 4-20 mA, Digital, PWM, Frequency/RPM or Counter). The modules can be connected to a variety of analog machine sensors or levers, PLC’s, switches, PWM signals, etc. It interfaces with the machine’s CAN network (CANopen). Standard embedded software is provided. Rugged packaging in addition to a wide-ranging power supply input section for 12V or 24Vdc power suits applications in the harsh environment of mobile equipment with on-board battery power. All setpoints are user configurable using commercially available CANopen® tools. |
N/A The 18 Digital Signal Input Module accepts up to 10 digital type inputs (active high/active low, PWM signal, Frequency or counter). Eight additional digital inputs are user selectable as Active High or Active Low. The electroni control can be connected to a variety of machine switches, sensors, PWM signals, etc. It interfaces with the machine’s CAN network (SAE J1939). Standard embedded software is provided. Rugged packaging in addition to a wide-ranging power supply input section for 12V or 24Vdc power suits applications in the harsh environment of mobile equipment with on-board battery power. All setpoints are user configurable using the Electronic Assistant. | |||
Order Code | N/A P/N: AX030310 (SAE J1939, Auto baud rate detect) | N/A P/N: AX030311 (CANopen®, configurable baud rate) | N/A P/N: AX030320 (SAE J1939, 250 kBit/s ) | |||
Operating Voltage | N/A 12V, 24VDC nominal (8…36VDC power supply range) | N/A 12V, 24VDC Nominal 8…36VDC Power Supply Range | N/A 12V, 24VDC nominal (8…36VDC power supply range) | |||
Inputs |
N/A
Up to 10 digital inputs are user selectable from the following: Active High/Active Low PWM signal from sensors or diesel engines ECM's Frequency (Hz or RPM) Counter Up to 8 digital inputs are user selectable as Active High/Active Low. |
|||||
Communications | N/A 1 CAN port (2.0B, SAE J1939). Auto-baud-rate detect. | N/A 1 CAN 2.0B port, Protocol CiA CANopen® | N/A 1 CAN port (SAE J1939) 250kbit/s | |||
Control Logic | N/A Standard Embedded Software User programmable functionality using Electronic Assistant. (Application-specific logic is available on request.) | N/A Standard embedded control logic is provided. User programmable functionality uses SDO object access with commercially available CANopen® tools. An EDS File is provided. | N/A Standard Embedded Software User programmable functionality using Electronic Assistant. (Application-specific logic is available on request.) | |||
Enclosure |
N/A
High Temperature Nylon housing - TE Deutsch PCB Enclosure (EEC-325X4B): 4.64 x 5.23 x 1.41 inches (117.90 x 132.90 x 35.80 mm) (W x L x H Excluding Mating Connectors) |
|||||
Protection Rating | N/A IP67 | |||||
Operating Temperature | N/A -40 to 85 ºC-40 to 185 ºF | N/A -40 to 85 ºC-40 to 85 ºF | N/A -40 to 85 ºC-40 to 85 ºF | |||
Compliance | N/A CE marking EMC Directive Exempt from Low Voltage Directive RoHS Directive | |||||
Applications |
N/A
Engine controls for commercial vehicles, off-highway equipment, etc. Engine controls for power generation, co-generation, stationary power. |
N/A
Engine controls for power generation, co-generation, stationary power. |
N/A Engine controls for commercial vehicles, off-highway equipment, etc. Engine controls for power generation, co-generation, stationary power. | |||
Accessories |
N/A
AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions) PL-DTM06-12SA-12SB, Mating Plug KIT (DTM06-12SA, DTM06-12SB, 2 WM12S, 24 Contacts, Plugs) |
N/A
PL-DTM06-12SA-12SB, Mating Plug KIT (DTM06-12SA, DTM06-12SB, 2 WM12S, 24 Contacts, Plugs) |
N/A
AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions) |
|||
|