The CAN to 2 Analog/ Digital Outputs Converter features 2 Analog/Digital signal outputs configurable as: 0-5V; 0-10V; 4-20 mA; Frequency or PWM Signal as well as 1 Relay output. Communications are via 1 isolated SAE J1939 port. It is Operational 9…36 Vdc (12 Vdc or 24 Vdc). The Signal Converter meets the surge requirements of SAE J1445 and is designed for EMC compliance. The controller is configured with the Axiomatic Electronic Assistant.

Unit of Measure

Technical Specifications

N/A CAN to 2 Analog/Digital Isolated Signals and 1 Relay Output Converter

Order Code

N/A P/N: AX130770

Signal Outputs

N/A 2 Analog/Digital isolated signal outputs configurable as:
0-5V
0-10V
4 - 20 mA
Frequency or PWM Signal.

Relay Output

N/A 1 Relay Output

Communications

N/A 1 Isolated CAN (SAE J1939)

CAN Baud Rate

N/A 250 kbps

Control Logic

N/A Electronic Assistant AX070502 Pre-programmed with standard logic.

Enclosure

N/A High Temperature Nylon housing
TE Deutsch PCB Enclosure (EEC-325X4B)
4.677 x 5.236 x 1.417 inches
118.80 x 133.00 x 36.00 mm
(W x L x H excluding mating plugs)

Connections

N/A Integral TE Deutsch 12 pin receptacle (P/N: DTM13-12PA-R008).

Protection Rating

N/A IP67

Operating Temperature

N/A -40 to 85 ºC-40 to 185 ºF

Applications

N/A

Servo Applications

Throttle controls for marine engine applications.

Marks

N/A CE

Datasheet

N/A AX130770 Datasheet

User Manual

N/A AX1307x0 User Manual

2D Drawing

N/A AX130770-2D

STEP Files (3D)

N/A TEDeutsch12pinenclosure

Compliance

N/A EMC - DoC - AX031XXX_AX130XXX
LVD - DoC - All
RoHS - DoC - All

Accessories

N/A , Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions)
, Mating Plug KIT (1-12 Socket)