The Discrete I/O Module reads 12 discrete inputs and sets 8 Form C relay outputs while networking with other CAN devices (SAE J1939) in a machine control system. The unit is a battery powered device with the ability to withstand engine cranking, reverse polarity and transient power conditions. In engine applications, information is provided to the engine control system using single-frame J1939 application-specific PDU2 type messages. Outputs can be controlled by any input or CAN message. A bi-color LED indicates operational status.

Unit of Measure

Order Code

N/A P/N: AX031800

Operating Voltage

N/A 12VDC or 24VDC nominal (9…32 VDC power supply range)

Communications

N/A 1 CAN 2.0B port, protocol SAE J1939

Control Logic

N/A Designed to work either as a stand-alone module, or on a J1939 CAN network. When connected to the network, it automatically recognizes network connection, claims a network address and can be configured to perform application tasks. User programmable functionality using Electronic Assistant.

Enclosure

N/A Rugged aluminum housing, stainless steel end plates, neoprene gaskets
145.30 x 149.00 x 73.00 mm
(5.72 x 5.86 x 2.87 inches)
L x W x H

Protection Rating

N/A IP67, Pollution Degree 3 Rating per UL508

Operating Temperature

N/A -40 to 85 ºC-40 to 185 ºF

Outputs

N/A Sets 8 Form C relay outputs
Resistive load:
2A (NO)/2 A (NC) at 277 VAC
2 A (NO)/2 A (NC) at 30 VDC
2 A (NO)/2 A (NC) at 125 VAC

Applications

N/A

AX070200, Plug Kit: DT06-08A, W8S, sockets + DRC16-40S (no key), sockets

Inputs

N/A Reads twelve (12) discrete inputs (active low with pull-up resistors):
Low-Level input voltage: 0 to 0.8 V.
High-Level Input Voltage: 3.75 to +BAT
Input resistance: more than 5 kOhms.
Inputs have internal pull-up resistors.
The inputs have internal over and under voltage protection.

Isolation

N/A CAN

Relay Output

N/A Relay (8)

Marks

N/A CE / UKCA Marking for EMC and RoHS Directives

Digital

N/A Discrete (12)

CAN Baud Rate

N/A 250 kbps

Fieldbus

N/A SAE J1939

# Inputs

N/A 12

# Outputs

N/A 8

# of Connections

N/A 48

Enclosure (Filter)

N/A Box

Compliance

N/A CE Marking for EMC and RoHS Directives Marine Type Approvals: Lloyd’s Register TAC, CCS TAC, ABS PDA, RINA REACH-SVHC UL508 (April 2010) (FTPM2) – Controls for Stationary Engine Driven Assemblies and cUL C22.2 No. 14-10 (2010)

Accessories

N/A , Plug Kit: DT06-08A, W8S, sockets + DRC16-40S (no key), sockets
, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions)