The 11 Input to 9 Output CAN Controller takes 12VDC or 24VDC nominal inputs with surge and transient protection. The unit features reverse polarity, overvoltage, undervoltage and short circuit protections, alongside input and output isolation.
The controller belongs to a family of Axiomatic smart controllers with configurable internal architecture. This provides users with flexibility, allowing them to build their own custom controller with a required functionality from a set of predefined internal functional blocks using the PC-based Axiomatic Electronic Assistant software tool. Application programming is performed through the CAN interface, without disconnecting the controller from the user’s system.
Unit of Measure

Order Code

N/A P/N: AX031200

Operating Voltage

N/A 12 VDC or 24 VDC nominal (9…60 VDC Power Supply Range)
Shutdown Voltage is 7.5 VDC

Communications

N/A 2 Isolated CAN ports (SAE J1939), 250 kbps

Control Logic

N/A Standard embedded software is provided.
(Application-specific control logic or factory programmed set point file on request)
User programmable functionality using Electronic Assistant.

Enclosure

N/A High Temperature Nylon Housing, TE Deutsch P/N: EEC-5X650B
5.67 x 7.92 x 2.15 inches
(144.0 x 201.3 x 54.6 mm)
L x W x H including integral connector

Protection Rating

N/A IP67

Operating Temperature

N/A -40 to 85 ºC-40 to 185 ºF

Outputs

N/A 9 Outputs:
4 Isolated Analog Outputs (user selectable as 0-5V or 0-10V Voltage; or 4-20 mA, 0-20 mA Current)
4 Relay Outputs (2A@ 250V NO)
1 Output (2A) to drive a proportional or ON/OFF hydraulic valve

Applications

N/A Power Gen Set Engine Control Systems
Off-highway Machine Automation
Oil and Gas Equipment Automation

Inputs

N/A 11 Inputs, user selectable from the following:
4 Isolated Analog Inputs,
2 Isolated Digital Inputs,
1 Magnetic Pick Up Input,
4 Universal Inputs
Inputs and Power are isolated from the outputs and CAN.

Enclosure (Filter)

N/A Box

Datasheet

N/A AX031200 Datasheet

User Manual

N/A AX031200 User Manual

STEP Files (3D)

N/A FG-AX031200

Compliance

N/A LVD - DoC - All
RoHS - DoC - All

Accessories

N/A , Mating Plug Kit (DT06-12SA, DT06-12SB, DT06-12SC, DT06-12SD, 4 W12S-P012, 48 1462-201-16141 Contacts, 15 Sealing plugs)
, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions)