The 10 Universal Signal Input Module accepts up to 10 analog or digital type inputs (0- 5V, 0-10V, 0-20 mA, 4-20 mA, Digital, PWM, Frequency/RPM or Counter). The modules can be connected to a variety of analog machine sensors or levers, PLC’s, switches, PWM signals, etc. It interfaces with the machine’s CAN network (SAE J1939). Standard embedded software is provided. Rugged packaging in addition to a wide-ranging power supply input section for 12V or 24Vdc power suits applications in the harsh environment of mobile equipment with on-board battery power. All setpoints are user configurable using the Electronic Assistant.

Unit of Measure

Order Code

N/A P/N: AX030120

Operating Voltage

N/A 12VDC or 24VDC Nominal Operating Voltage 8…60 VDC Power Supply Range

Communications

N/A 1 CAN port (2.0B, SAE J1939) with Auto-Baud-Rate-Detection

Control Logic

N/A Standard embedded control logic is provided. User programmable functionality using Electronic Assistant.

Enclosure

N/A High Temperature Nylon housing - TE Deutsch PCB Enclosure (EEC-325X4B) with 24 pin receptacle.

Protection Rating

N/A IP67, Unit is Conformal Coated in the Housing

Operating Temperature

N/A -40 to 85 ºC-40 to 185 ºF

Applications

N/A

Commercial Vehicles
Material Handling Equipment
Power Generation
Standby Generators
Off-highway Construction Equipment
Forestry Mining and Military Vehicles

Inputs

N/A 10 user selectable signal inputs, user selectable from the following:
0-5 V
0-10 V
0-20 mA
4-20 mA
PWM (Low or High Frequency)
Frequency/RPM
Counter
Digital

Enclosure (Filter)

N/A Box

Compliance

N/A CE marking

Datasheet

N/A AX030120 Datasheet

User Manual

N/A AX0301x0 User Manual

2D Drawing

N/A AX030120-MD-A

STEP Files (3D)

N/A AX030120-A-STEP

Compliance

N/A EMC - DoC - AX03012X
LVD - DoC - All
RoHS - DoC - All

Accessories

N/A , Axiomatic Electronic Assistant KIT (USB-CAN Converter, USB-A to USB-B Cable, CAN Cable, Installation Instructions)
, Mating Plug KIT (DTM06-12SA, DTM06-12SB, 2 WM12S, 24 Contacts, Plugs)