The Universal Input to Single Output Valve Controller with LED is designed for versatile control of a universal input and a proportional valve output. Its flexible hardware design allows for the controller to have a wide range of input and output types. The sophisticated control algorithms/logical function blocks allow the user to configure the controller for a wide range of applications without the need for custom firmware. The setpoints are configurable using Axiomatic service tool, Electronic Assistant® (EA). The universal input can be configured to read analog signals: Voltage, Current, and Resistance as well as digital signals: Frequency/RPM, PWM, Digital, and Counter types. Similarly, the output can be configured to different types: Proportional Current, Voltage, PWM, Hotshot Digital Current and Digital (ON/OFF). Each output consists of a high side half-bridge driver able to source up to 3 Amps with hardware shutdown at 4 Amps. Additionally, the controller includes a dual LED which is visible from outside the housing. The LED can be configured in various ways to visually inform the user of the controller’s operations. It is ruggedly packaged for installation in wet, humid and dusty environments.
Technical Specifications |
N/A 1 Universal Input, 1 Output Valve Controller with LED, SAE J1939 |
Order Code |
N/A P/N: AX021610 |
Operating Voltage |
N/A 12Vdc or 24Vdc nominal |
Communications |
N/A 1 CAN (SAE J1939) |
Control Logic |
N/A Standard embedded software with user programmable setpoints and control profiles (Refer to datasheet). |
Enclosure |
N/A
Molded enclosure, integral connector Nylon 6/6, 30% glass Ultrasonically welded 3.47 x 2.75 x 1.31 inches 88.2 x 70.0 x 33.3 mm L x W x H including integral connector |
Connections |
N/A 8-pin connector. TE Deutsch equivalent P/N: DT04-08PA |
Outputs |
N/A
1 output that can be set to the following: Proportional Current (0-3 A) Proportional Voltage up to Vps PWM signal Hotshot digital Digital on/off Voltage 0-Vps (user selectable) |
Applications |
N/A
Industrial, off-highway (mobile) and marine applications for the control of hydraulic valves. Interface with a diesel engine’s electronic control module PWM signal to drive accessories. |
User Configurability |
N/A Electronic Assistant, P/N: AX070502 |
Inputs |
N/A 1 universal signal input that can be set to Voltage, Current, Resistive, PWM, Frequency or Digital. |
Indicator |
N/A User configurable to react to different events or faults. |
LED Outputs |
N/A User configurable to react to different events or faults |
Marks |
N/A CE |
Digital |
N/A Counter (1) Digital (1) Frequency (1) PWM (1) |
Resistive Inputs |
N/A 0.025 - 250 (1) kΩ |
CAN Baud Rate |
N/A 250 kbps |
Fieldbus |
N/A SAE J1939 |
# Inputs |
N/A 1 |
# Outputs |
N/A 1 |
Analog (V or mA) |
N/A 0-1V, 0-2.5V, 0-5 V, 0-10 V (1) 4-20 mA, 0-20 mA (1) |
Proportional and On/Off Solenoid |
N/A 1 (3A) |
# of Connections |
N/A 8 |
Enclosure (Filter) |
N/A Box |
Datasheet |
N/A
AX021610 Datasheet |
User Manual |
N/A
AX021610 User Manual |
2D Drawing |
N/A
AX021610-2D |
STEP Files (3D) |
N/A
AX021610 |
Compliance |
N/A
EMC - DOC - AX021610 LVD - DoC - All RoHS - DoC - All |