The controller drives up to 6 on/off valves at 5 Amps over a CANopen network. Alternatively, the user can select pulsed, timed or PWM output types. It accepts up to 2 analog inputs (0-5v, 0-20 mA or 4-20 mA) and 3 digital inputs for connection to a variety of analog machine sensors or levers. The user can also select PWM, Frequency/RPM or 16-bit Counter inputs. Each input can be configured to measure the input value and send the data to a CANopen network. In addition, any output on the controller could be configured information from the CAN bus. Standard embedded software is provided. An EDS file is provided to interaface to standard CANopen tools. A valuable diagnostic feature involves reading and retaining in the unit’s memory the actual current draw form the solenoid(s). Rugged packaging in addition to a 9-36V power supply input section suits mobile equipment control applications.

Unit of Measure

Order Code

N/A P/N: AX021301 (CANopen®)

Operating Voltage

N/A 12V or 24VDC nominal (9…36VDC)

Communications

N/A 1 CAN (CANopen®), 1 RS-232

Control Logic

N/A Standard embedded software with user selectable setpoints and control options (Refer to datasheet.)

Enclosure

N/A High Temperature Nylon housing
TE Deutsch PCB Enclosure (EEC-325X4B)
24-pin connector
4.62 x 5.24 x 1.43 inches
117.42 x 133.09 x 36.36 mm
WxLxH excluding mating plug)

Protection Rating

N/A IP67

Outputs

N/A 6 outputs are user selectable from the following:
Digital
Timed
Pulsed
PWM

The output response is user selectable from the following:
Disabled
Normal On/Off
Inverted On/Off
Latched

High Side (sourcing)
Drives up to 6 On/Off Valves (up to 5A each)

User Configurability

N/A EDS provided to interface to standard CANopen® tools.

Inputs

N/A 2 user selectable analog inputs
(0-5V, 0-20 mA, 4-20 mA, PWM, Frequency/RPM, Digital Active High)
3 user selectable frequency inputs
(Digital Active High, Digital Active Low, PWM, Frequency/RPM)

Enclosure (Filter)

N/A Box

Datasheet

N/A AX021301 Datasheet

User Manual

N/A AX021301 User Manual

STEP Files (3D)

N/A TEDeutsch24pinEnclosure

EDS

N/A AX021301EDS

Compliance

N/A LVD - DoC - All
RoHS - DoC - All