Items |
/Asset/AX188000.jpg AX188000 2 Thermocouple Inputs, SAE J1939 CAN Controller |
/Asset/AX188001.gif AX188001 2 Thermocouple Inputs, CANOpen Controller |
/Asset/AX188000-01.jpg AX188000-01 2 Thermocouple Inputs, SAE J1939 CAN Controller, 500kbps |
/Asset/AX188000-02.jpg AX188000-02 2 Thermocouple Inputs, SAE J1939 CAN Controller, 1 Mbps |
||||
Description |
N/A
The Thermocouple Module monitors up to 2 channels of Type J, K, B, E, N, R, S or T thermocouples (others on request). The temperature information is provided to the engine control system over SAE J1939 CAN bus. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All channels are fully isolated and measure temperatures at the same time. Temperature data is automatically sent over the CAN bus when power is applied. During set-up, using an USB-CAN converter and a PC, the operator can configure the controller via the Axiomatic Electronic Assistant to suit a wide variety of applications. |
N/A
The Thermocouple Module monitors up to 2 channels of Type J, K, B, E, N, R, S or T thermocouples (others on request). The temperature information is provided to the engine control system over CAN bus. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All channels are fully isolated and measure temperatures at the same time. Temperature data is automatically sent over the CAN bus when power is applied. Settings are automatically saved to non-volatile memory. The product enclosure is rated as IP67 and has an 8 pin connector. |
N/A The Thermocouple Module monitors up to 2 channels of Type J, K, B, E, N, R, S or T thermocouples (others on request). The temperature information is provided to the engine control system over SAE J1939 CAN bus. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All channels are fully isolated and measure temperatures at the same time. Temperature data is automatically sent over the CAN bus when power is applied. During set-up, using an USB-CAN converter and a PC, the operator can configure the controller via the Axiomatic Electronic Assistant to suit a wide variety of applications. | N/A The Thermocouple Module monitors up to 2 channels of Type J, K, B, E, N, R, S or T thermocouples (others on request). The temperature information is provided to the engine control system over SAE J1939 CAN bus. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All channels are fully isolated and measure temperatures at the same time. Temperature data is automatically sent over the CAN bus when power is applied. During set-up, using an USB-CAN converter and a PC, the operator can configure the controller via the Axiomatic Electronic Assistant to suit a wide variety of applications. | ||||
Technical Specifications | N/A Thermocouple Module, 2 Channel, SAE J1939 | N/A Thermocouple Module, 2 Channel, CANopen | N/A Thermocouple Module, 2 Channel, 500 kbps SAE J1939 | N/A Thermocouple Module, 2 Channel, 1 Mbps SAE J1939 | ||||
Order Code | N/A P/N: AX188000 | N/A P/N: AX188001 (Thermocouple Module, 6 Channels, CANopen) | N/A P/N: AX188000-01 | N/A P/N: AX188000-02 | ||||
Operating Voltage | N/A 12V or 24Vdc nominal | N/A 12V or 24Vdc nominal | N/A 12 or 24 VDC nominal | N/A 12 or 24VDC nominal | ||||
Protection | N/A Surge and Reverse Polarity Protection Provided | |||||||
Inputs | N/A 2 Type J, K, B, E, N, R, S or T TC | |||||||
CAN Baud Rate | N/A 250 kbps | N/A | N/A 500 kbps | N/A 1 Mbps | ||||
Enclosure |
N/A
Molded Enclosure, Integral Connector Nylon 6/6, 30% Glass, Ultrasonic Welded 3.47 x 2.75 x 1.31 Inches 88.2 x 70.0 x 33.3 mm L x W x H Including Integral Connectors |
N/A
Molded Enclosure, Integral Connector Nylon 6/6, 30% Glass, Ultrasonic Welded 3.47 x 2.75 x 1.31 Inches 88.2 x 70.0 x 33.3 mm L x W x H Including Integral Connectors |
N/A
Molded Enclosure, Integral Connector Nylon 6/6, 30% Glass, Ultrasonic Welded 3.47 x 2.75 x 1.31 Inches 88.2 x 70.0 x 33.3 mm L x W x H Including Integral Connectors |
N/A
Molded Enclosure, Integral Connector Nylon 6/6, 30% Glass, Ultrasonic Welded 3.47 x 2.75 x 1.31 Inches 88.2 x 70.0 x 33.3 mm L x W x H Including Integral Connectors. |
||||
Connections | N/A TE Deutsch 8-pin Receptacle (P/N: DT04-08PA). | |||||||
Protection Rating | N/A IP67 | |||||||
CAN | N/A Isolated SAE J1939 | N/A Isolated CANopen® | N/A 1 CAN port (SAE J1939) | N/A 1 CAN port (SAE J1939) | ||||
Isolation | N/A | N/A |
N/A
Full isolation of each channel from the CAN line, other inputs and power supply. Isolation voltage is 1500 Vac (rms) or 2550V for 1 sec. for all channels to power and 50V (rms) for all channels to CAN interface. |
N/A
Full isolation of each channel from the CAN line, other inputs and power supply. Isolation voltage is 1500 Vac (rms) or 2550V for 1 sec. for all channels to power and 50V (rms) for all channels to CAN interface |
||||
Applications | N/A Power Generator Sets | |||||||
Accessories |
N/A
AX070112, Plug Kit: DT06-08SA, W8S, 0462-201-16141, 114017 AX070502, Axiomatic Electronic Assistant KIT (USB-CAN Converter, USB-A to USB-B Cable, CAN Cable, Installation Instructions) AX070505K, Axiomatic Electronic Assistant KIT (USB-CAN Converter, USB-A to Micro USB-B Cable, CAN Cable, Installation Instructions) |
|||||||
|