The controller features four universal signal inputs configurable as Voltage, Current, Resistive, Frequency, PWM, or Digital. Depending on the model, it communicates through CAN (SAE J1939) or CANopen®. The user can select +8V or +5V Reference. The unit is in a compact IP67 enclosure, and operates from -40°C to +85°C.

Unit of Measure

Operating Voltage

N/A 12 VDC or 24 VDC Nominal (8…36 VDC)

Protection

N/A Over-voltage protection is up to 59 V. Reverse polarity protection up to -36V. Under-voltage shutdown at 5.1 V.

Inputs

N/A Four universal signal inputs configurable as:
Voltage, Current, Resistive, Frequency, PWM, or Digital

Communications

N/A 1 CAN port ( CANopen®)

CAN Baud Rate

N/A Selectable

Control Logic

N/A Standard embedded software is provided.
(Application-specific control logic or a set point file is available on request.)

Enclosure

N/A Molded Enclosure, integral connector
Nylon 6/6, 30% Glass
Ultrasonically Welded
3.54 x 2.75 x 1.31 inches
(90.09 x 70.00 x 33.35 mm)
L x W x H including integral connector

Electrical Connections

N/A Integral TE Deutsch 12 pin receptacle (P/N: DTM04-12PA)

Protection Rating

N/A IP67

Operating Temperature

N/A -40 to 85 ºC-40 to 185 ºF

Marks

N/A CE / UKCA

Applications

N/A

Machine Automation

Reference Voltage

N/A +8V Reference, +5V Reference (user selectable)

Datasheet

N/A AX030441 Datasheet

User Manual

N/A AX0304X1 User Manual

EDS

N/A EDS-21141-1-0

2D Drawing

N/A AX030441-MD-A

STEP Files (3D)

N/A 12-Pin Laser Welded Assembly

Compliance

N/A LVD - DoC - All
RoHS - DoC - All

Accessories

N/A , Mating Plug KIT (1-12 Socket)