The 12 Channel Strain Gauge CAN controller accepts up to twelve 4-wire strain gauge connections. The input range is user selectable from +/- 2.5 mV to +/- 2.5 Vdc. The measurement rate is 1000 scans per second for all 12 channels. It interfaces with the machine’s CAN network (SAE J1939). Two CAN ports are provided. The measurement rate and the update rate are high speed for all channels. Standard embedded software is provided. Rugged IP66 rated packaging and a power supply input of 12V, 24V or 48Vdc nominal suits applications in the harsh environment of mobile equipment with on-board battery power. All setpoints are user configurable using the Electronic Assistant.
Unit of Measure
Order Code |
N/A P/N: AX200102 (SAE J1939 Controller, 250 kbps baud rate) |
Operating Voltage |
N/A 12V, 24V or 48Vdc Nominal (7…61 Vdc Power Supply Range) Suitable for Engine Cranking and Load Dump |
Inputs |
N/A 1 Digital Input (Push Button) 12 +5V or +10V Excitation Connections |
Strain Gauge Inputs |
N/A
12 channels for inputs from 4-wire full bridge strain gauges: Input range is selectable from +/- 2.5mV to +/- 2.5VDC. The measurement rate is 1000 scans per second for all 12 channels. |
Communications |
N/A 2 CAN ports (SAE J1939) Auto-Baud-Rate-Detect |
Control Logic |
N/A Standard embedded software is provided and is configurable using the Electronic Assistant (EA). Refer to the User Manual. |
Enclosure |
N/A
Cast Aluminum, Hard Anodized 7.250 x 3.750 X 2.216 inches 184.15 x 95.25 x 56.30 mm (L X W X H) |
Connections |
N/A
6 CONEC M12 8-pin connectors (A-coded), P/N: 43-01332 (Ports 1-6) 1 CONEC M12 8-pin connector (A-coded) P/N: 43-01014 (Port 7) |
Protection Rating |
N/A IP66 |
Operating Temperature |
N/A -40 to 85 ºC-40 to 185 ºF |
Datasheet |
N/A
AX200102 Datasheet |
User Manual |
N/A
AX200102 User Manual |
STEP Files (3D) |
N/A
AX200102-02 |
Compliance |
N/A
LVD - DoC - All RoHS - DoC - All |
Accessories |
N/A
AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions) |