This products features 1 Digital signal input up to +Vps (ignition switch) and 2 Digital outputs up to 4A. It comes in a compact, fully sealed enclosure, with IP67 protection. This product meets the surge requirements of SAE J1445.

Unit of Measure

Order Code

N/A P/N: AX032200 (1 Digital Input, 2 Digital Outputs Valve Controller, SAE J1939 with auto-baud-rate detect)

Operating Voltage

N/A 12 V or 24 Vdc Nominal; 8…36 Vdc The minimum allowable supply voltage for the power pin is 7 VDC.

Communications

N/A 1 CAN (SAE J1939)

Enclosure

N/A Molded Enclosure, Integral Connector
Nylon 6/6, 30% Glass
Ultrasonically Welded
3.47 x 2.75 x 1.31 Inches
(88.2 x 70.0 x 33.3 mm)
L x W x H Including Integral Connector

Connections

N/A Integral 8-pin receptacle (TE Deutsch equivalent P/N: DT04-08PA)

Protection Rating

N/A IP67

Operating Temperature

N/A -40 to 125 ºC-40 to 257 ºF

Outputs

N/A 2 Digital Outputs (up to 4A Sourcing)
High Side
Current Sensing, Grounded Load
Overcurrent Protected Against Shorts to GND or +Vps
Digital On/Off: Sourcing from Power Supply or Off
Load at Supply Voltage must not Draw more than 4A

Applications

N/A

Ignition switch operated valve controller for on/off valves.

Inputs

N/A 1 Ignition Signal Input
0 to +Vps
Optional Input Configuration as One Digital Input with 10K Pull-up or Pull-down
Protected against shorts to Ground or +Vps

Enclosure (Filter)

N/A Box

Datasheet

N/A AX032200 Datasheet

User Manual

N/A AX032200 User Manual

2D Drawing

N/A AX032200-MD-P1

STEP Files (3D)

N/A 12-Pin Laser Welded Assembly

Compliance

N/A LVD - DoC - All
RoHS - DoC - All

Accessories

N/A , Plug Kit: DT06-08SA, W8S, 0462-201-16141, 114017
, Axiomatic Electronic Assistant KIT (USB-CAN Converter, USB-A to USB-B Cable, CAN Cable, Installation Instructions)