There are 12 digital inputs that are user selectable from Active High/Active Low, and 3 universal signal inputs that are selectable as: Voltage, Current, Resistance, Frequency, PWM or Digital. It features 12V, 24V or 48Vdc input power (nominal) with rugged surge protection. It is user configurable using Axiomatic Electronic Assistant.


Unit of Measure

Technical Specifications

N/A 12 Digital Signal Inputs, 1 TC Input Controller, SAE J1939, Auto-baud-rate Detect

Order Code

N/A P/N: AX030340

Control Logic

N/A AX070502 Electronic Assistant KIT (includes the USB-CAN Converter, cables and EA Software.
The Electronic Assistant is for Windows operating systems.
It comes with a royalty-free license for use.)

Enclosure

N/A High Temperature Nylon housing – TE Deutsch Enclosure (EEC-325X4B)

Connections

N/A Deutsch DTM series 24 pin receptacle (DTM13-12PA-12PB-R008). Mating plug: Deutsch DTM06-12SA and DTM06-12SB with 2 wedgelocks (WM12S) and 24 contacts (0462-201-20141).
20 AWG wire is recommended for use with contacts 0462-201-20141.

Operating Temperature

N/A -40 to 85 ºC-40 to 185 ºF

Protection

N/A Protected against shorts to GND or +V supply.

Applications

N/A

Engine controls for commercial vehicles, off-highway equipment, etc.

Engine controls for power generation, co-generation, stationary power.

Isolation

N/A 200Vrms Full isolation of TC input channel from the CAN line, other inputs and power supply.

CAN

N/A 1 CAN port (SAE J1939)

Weight

N/A 0.55 (preliminary) lb0.23 (preliminary) kg

Vibration

N/A Random Vibration: 7.65 Grms peak.
Sinusoidal Component: 10 g peak.
Based on MIL-STD-202G, Methods 204G and 214A.

Shock

N/A 50 g half sine pulse, 6 x 6ms per axis. Based on MIL-STD-202G, Method 213B, Test Condition A.

CAN Baud Rate

N/A SAE J1939, 250kbit/s, 500kbit/s, 667kbit/s, 1Mbit/s. Automatic Baud Rate Detection

Protection for CAN Port

N/A Short Circuit to Ground

Network Termination

N/A 120 Ohm terminated twisted pair, baud rate up to 1Mbit/s. External 120 Ohm termination is required.

Enclosure (Filter)

N/A Box

Compliance

N/A CE Mark:
EMC Directive
Exempt from Low Voltage Directive RoHS Directive

Accessories

N/A , Axiomatic Electronic Assistant KIT (USB-CAN Converter, USB-A to USB-B Cable, CAN Cable, Installation Instructions)