Unit of Measure

Operating Voltage

N/A 12Vdc or 24Vdc Nominal (8…36VDC)

Communications

N/A 1 CAN port (SAE J1939), CANopen is available in model AX022001.

Control Logic

N/A User programmable functionality using Electronic Assistant.
Refer to UMAX07050X for details.
(Application-specific control logic or factory programmed setpoints are available on request.)

Enclosure

N/A Aluminum enclosure, integral TE Deutsch connector. Encapsulated Refer to the dimensional drawing.

Outputs

N/A 2 Proportional or On/Off Outputs (Up to 3A). High Side Switch, Current Sensing, Grounded Load. The user can select the following options for output using EA:
Output Disable
Discrete Output
Output Current (PID loop, with current sensing)
Output Voltage
Output PWM Duty Cycle

Applications

N/A Industrial, off-highway (mobile) and marine applications for the control of hydraulic valves. Interface with a diesel engine’s electronic control module PWM signal to drive accessories.

User Configurability

N/A Electronic Assistant Kit for Windows operating systems, P/N: AX070502 It comes with a royalty-free license for use on multiple computers.

Inputs

N/A 1 Universal Signal Input

Reference Voltage

N/A +5V, 10 mA, 0.5% Protected from connection to the power supply rail. Short circuit protected (current limited to 22-24 mA).

Datasheet

N/A AX022003 Datasheet

User Manual

N/A AX022003 User Manual

2D Drawing

N/A AX022003-2D

STEP Files (3D)

N/A DT15-12PA Generic Enclosure

Compliance

N/A AX02200X EMC
LVD - DoC - All
RoHS - DoC - All

Accessories

N/A , Plug Kit (DT06-12SA, W12S, 0462-201-16141, 114017)
, Axiomatic Electronic Assistant KIT (USB-CAN Converter, USB-A to USB-B Cable, CAN Cable, Installation Instructions)