The Universal Input to Single Output Valve Controller with LED is designed for versatile control of a universal input and a proportional valve output. Its flexible hardware design allows for the controller to have a wide range of input and output types. The sophisticated control algorithms/logical function blocks allow the user to configure the controller for a wide range of applications without the need for custom firmware. The setpoints are configurable using standard CANopen® tools. The universal input can be configured to read analog signals: Voltage, Current, and Resistance as well as digital signals: Frequency/RPM, PWM, Digital, and Counter types. Similarly, the output can be configured to different types: Proportional Current, Voltage, PWM, Hotshot Digital Current and Digital (ON/OFF). Each output consists of a high side half-bridge driver able to source up to 3 Amps with hardware shutdown at 4 Amps. Additionally, the controller includes a dual LED which is visible from outside the housing. The LED can be configured in various ways to visually inform the user of the controller’s operations.
Technical Specifications |
N/A 1 Input, 1 Output Valve Controller, CANopen |
Order Code |
N/A P/N: AX021611 |
Operating Voltage |
N/A 12Vdc or 24Vdc nominal |
Communications |
N/A CANopen® |
Control Logic |
N/A Standard embedded software with user programmable setpoints and control profiles (Refer to datasheet). |
Enclosure |
N/A
Molded enclosure, integral connector Nylon 6/6, 30% glass Ultrasonically welded 3.47 x 2.75 x 1.31 inches 88.2 x 70.0 x 33.3 mm L x W x H including integral connector |
Connections |
N/A 8-pin connector TE Deutsch equivalent P/N: DT04-08PA |
Outputs |
N/A
1 output that can be set to the following: Proportional Current (0-3 A) Proportional Voltage up to Vps PWM signal Hotshot digital Digital on/off Voltage 0-Vps (user selectable) |
Applications |
N/A
Interface with a diesel engine’s electronic control module PWM signal to drive accessories. |
User Configurability |
N/A An EDS file is provided to interface with CANopen® tools. |
Inputs |
N/A 1 universal signal input that can be set to Voltage, Current, Resistive, PWM, Frequency or Digital. |
Indicator |
N/A User configurable to react to different events or faults. |
LED Outputs |
N/A LED |
Marks |
N/A CE |
Digital |
N/A Counter (1) Digital (1) Frequency (1) PWM (1) |
Resistive Inputs |
N/A 0.025 - 250 (1) kΩ |
CAN Baud Rate |
N/A Selectable |
Fieldbus |
N/A CANopen |
# Inputs |
N/A 1 |
# Outputs |
N/A 1 |
Proportional and On/Off Solenoid |
N/A 1 (3A) |
# of Connections |
N/A 8 |
Enclosure (Filter) |
N/A Box |
Datasheet |
N/A
AX021611 Datasheet |
User Manual |
N/A
AX021611 User Manual |
STEP Files (3D) |
N/A
AX021610 |
EDS |
N/A
EDS-AX021611 |
Compliance |
N/A
EMC - DOC - AX021610 LVD - DoC - All RoHS - DoC - All |
Accessories |
N/A
AX070112, Plug Kit: DT06-08SA, W8S, 0462-201-16141, 114017 |