The CAN to Dual Output Valve Controller is a highly programmable controller, allowing the user to configure it for their application. It must be integrated into a CANopen® network of controllers. Its sophisticated control algorithms allow for open or closed loop drive of the proportional outputs. All logical function blocks on the unit are inherently independent but can be programmed to interact in a large number of ways.
Unit of Measure
Technical Specifications |
N/A (24 Vdc) CAN to 2 Output Valve Controller, CANopen with LED |
Order Code |
N/A P/N: AX020201 (CANopen) |
Operating Voltage |
N/A 12Vdc or 24Vdc nominal (9...36 power supply range) The design is suited for engine cranking and load dump conditions. |
Communications |
N/A 1 CANopen |
Control Logic |
N/A Standard embedded software with user programmable setpoints and control profiles (Refer to datasheet). |
Enclosure |
N/A
Molded Enclosure, Integral Connector Nylon 6/6, 30% Glass Ultrasonically Welded 88.2 x 70.0 x 33.3 mm 3.47 x 2.75 x 1.31 inches L x W x H Including Integral Connectors |
Connections |
N/A 8-pin connector. TE Deutsch P/N: DT04-08PA. |
Outputs |
N/A Two independent software controlled outputs selectable as: Proportional Current (up to 2.5A); Hotshot Digital; PWM Duty Cycle; Proportional Voltage; or On/Off Digital types (3A) |
Applications |
N/A
The controller is designed to meet the rugged demands of mobile equipment and heavy duty industrial machine control applications, such as PID closed loop valve control and hydraulic valve control. |
User Configurability |
N/A EDS File for CANopen® Model |
Indicator |
N/A User configurable to react to different events or faults. |
Datasheet |
N/A
AX020201 Datasheet |
User Manual |
N/A
AX020201 User Manual |
2D Drawing |
N/A
AX020201-2D |
STEP Files (3D) |
N/A
AX020200 |
EDS |
N/A
EDSAX020201 |
Compliance |
N/A
EMC - DoC - AX020200 FCC- DoC - AX020200 LVD - DoC - All RoHS - DoC - All UKCA - DoC - AX020200 |
Accessories |
N/A
AX070112, Plug Kit: DT06-08SA, W8S, 0462-201-16141, 114017 |