Items |
/ImgCustom/20/placeholder_notavailable.gif RSDDR10V-0000001 RSD-DR-10V-2A, 10V, 2A Remote Mount Solenoid Driver, DIN Rail Mount |
/ImgCustom/20/placeholder_notavailable.gif RSDDR10V-0000002 RSD-DR-10V-1.2A, 10V, 1.2A Remote Mount Solenoid Driver, DIN Rail Mount |
/Asset/RSD-DR-10V-400MA.jpg RSDDR10V-0000005 RSD-DR-10V-400MA, 10V, 400mA Remote Mount Solenoid Driver, DIN Rail Mount |
/Asset/RSDPCB10V-0000004.jpg RSDPCB10V-0000004 RSD-PCB-10V-2A PCB 10V, 2A Remote Mount Solenoid Driver, PCB |
/ImgCustom/20/placeholder_notavailable.gif RSDSMB10V-0000017 RSD-SMB-10V-400MA-00 10V, 400 mA Remote Mount Solenoid Driver, Metal Box, Strain Relief |
|||||
Description |
N/A
The Remote Mount Solenoid Driver simplifies control of proportional solenoids by supplying a current proportional to a 0-10V input signal. It utilizes high frequency switching output (PWM) to provide a DC current output. Current outputs vary by model number. The user can adjust maximum and minimum current, ramp time, dither frequency and amplitude. |
N/A The Remote Mount Solenoid Driver simplifies control of proportional solenoids by supplying a current proportional to a 0-10V input signal. It utilizes high frequency switching output (PWM) to provide a DC current output. Current outputs vary by model number. The user can adjust maximum and minimum current, ramp time, dither frequency and amplitude. | N/A The Remote Mount Solenoid Driver simplifies control of proportional solenoids by supplying a current proportional to a 0-10V input signal. It utilizes high frequency switching output (PWM) to provide a DC current output. Current outputs vary by model number. The user can adjust maximum and minimum current, ramp time, dither frequency and amplitude. |
N/A
The Remote Mount Solenoid Driver simplifies control of proportional solenoids by supplying a current proportional to a 0-10V input signal. It utilizes high frequency switching output (PWM) to provide a DC current output. Current outputs vary by model number. The user can adjust maximum and minimum current, ramp time, dither frequency and amplitude. |
N/A
The Remote Mount Solenoid Driver simplifies control of proportional solenoids by supplying a current proportional to a 0-10V input signal. It utilizes high frequency switching output (PWM) to provide a DC current output. Current outputs vary by model number. The user can adjust maximum and minimum current, ramp time, dither frequency and amplitude. |
|||||
Operating Voltage | N/A 9...28 VDC Accepts up to a maximum of 32 VDC | |||||||||
Inputs |
N/A
0-10 VDC voltage signal, or 0-20 mA current signal |
|||||||||
Range of Maximum Output Current | N/A 2A | N/A 1.2A | N/A 400 mA | N/A 2A | N/A 400 mA | |||||
Enclosure |
N/A
DIN Rail Mount 90.0 x 68.0 x 70.0 mm 3.54 x 2.67 x 2.75 inches (W x L x H excluding foot) |
N/A
DIN Rail Mount 90.0 x 68.0 x 70.0 mm 3.54 x 2.67 x 2.75 inches (W x L x H excluding foot) |
N/A
DIN Rail Mount 90.0 x 68.0 x 70.0 mm 3.54 x 2.67 x 2.75 inches (W x L x H excluding foot) |
N/A
PCB only 63.5 x 20.3 x 63.5 mm (W x D x H) 2.5 x 0.8 x 2.5 inches |
N/A
Metal box with Strain Relief 114.3 x 27.9 x 79.4 mm 4.50 x 1.01 x 3.13 inches (W x D x H) |
|||||
Connections | N/A 10 screw terminals accept 16-20 AWG wire for the power conductors and 18-24 AWG wire for the signal conductors | N/A 10 screw terminals accept 16-20 AWG wire for the power conductors and 18-24 AWG wire for the signal conductors | N/A 10 screw terminals accept 16-20 AWG wire for the power conductors and 18-24 AWG wire for the signal conductors | N/A 10 screw terminals accept 16-20 AWG wire for the power conductors and 18-24 AWG wire for the signal conductors | N/A PG-9 Strain Relief, 10 Screw Terminals | |||||
Protection Rating |
N/A
IP00 Circuit board is conformally coated. |
N/A
IP00 Circuit board is conformally coated. |
N/A
IP00 Circuit board is conformally coated. |
N/A
IP00 Circuit board is conformally coated. |
N/A IP65 | |||||
Operating Temperature | N/A -40 to 85 ºC-40 to 185 ºF | |||||||||
Compliance |
N/A
CE Emission EN 50081-2 Immunity EN 50082-2 |
N/A
CE Emission EN 50081-2 Immunity EN 50082-2 |
N/A
CE Emission EN 50081-2 Immunity EN 50082-2 |
N/A |
N/A
CE Emission EN 50081-2 Immunity EN 50082-2 |
|||||
Applications |
N/A
Accurate control of hydraulic and pneumatic proportional solenoid valves used in mobile equipment and industrial processes. |
N/A Accurate control of hydraulic and pneumatic proportional solenoid valves used in mobile equipment and industrial processes. | N/A Accurate control of hydraulic and pneumatic proportional solenoid valves used in mobile equipment and industrial processes. | N/A Accurate control of hydraulic and pneumatic proportional solenoid valves used in mobile equipment and industrial processes. |
N/A
Accurate control of hydraulic and pneumatic proportional solenoid valves used in mobile equipment and industrial processes. |
|||||
STEP Files (3D) |
N/A
RSDDR10V-0000001 |
N/A | N/A | N/A | N/A | |||||
|