The Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (0-5V or 0-20mA or 10K potentiometer or pre-set level). It accepts power supply voltages from 9 to 28VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The options for current output include 2A, 1.2A, 800mA or 600mA. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current, ramp times, dither frequency, and amplitude to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. Other versions are available with 4-20mA or 0-10V inputs. A remote mount version is housed in a rugged metal box.

Unit of Measure
Items
CAPV-H-5V-x Connector Amplifier For Proportional Valves

CAPV-H-5V-2A c/w CAPV-6C-2M Connector Amplifier, 5VDC Input, 2A Output, DIN 43650A, 2m Cable

CAPV-H-5V-x Connector Amplifier For Proportional Valves

CAPV-H-5V-1.2A-6C-2M Connector Amplifier, 5VDC Input, 1.2A Output, DIN 43650A, 2m Cable

CAPV-H-5V-x Connector Amplifier For Proportional Valves

CAPV-H-5V-800MA-6C-2M Connector Amplifier, 5VDC Input, 800 mA Output, DIN 43650A, 2m Cable

CAPV-H-5V-x Connector Amplifier For Proportional Valves

Connector Amplifier, 5VDC Input, 600 mA Output, DIN 43650A, 2m Cable

CAPV-H-5V-x Connector Amplifier For Proportional Valves

Connector Amplifier, 0-5V input, 2A Output, DIN43650A, 8 m Cable
Description N/A

The Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (0-5V or 0-20mA or 10K potentiometer or pre-set level). It accepts power supply voltages from 9 to 28VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The current output is 2A. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current, ramp times, dither frequency, and amplitude to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. Other versions are available with 4-20mA or 0-10V inputs. A remote mount version is housed in a rugged metal box.

 
N/A

The Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (0-5V or 0-20mA or 10K potentiometer or pre-set level). It accepts power supply voltages from 9 to 28VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The current output is 1.2A. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current, ramp times, dither frequency, and amplitude to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. Other versions are available with 4-20mA or 0-10V inputs. A remote mount version is housed in a rugged metal box.

 
N/A

The Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (0-5V or 0-20mA or 10K potentiometer or pre-set level). It accepts power supply voltages from 9 to 28VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The current output is 800mA. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current, ramp times, dither frequency, and amplitude to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. Other versions are available with 4-20mA or 0-10V inputs. A remote mount version is housed in a rugged metal box.

 
N/A

The Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (0-5V or 0-20mA or 10K potentiometer or pre-set level). It accepts power supply voltages from 9 to 28VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The current output is 600mA. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current, ramp times, dither frequency, and amplitude to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. Other versions are available with 4-20mA or 0-10V inputs. A remote mount version is housed in a rugged metal box.

 
N/A

The Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (0-5V or 0-20mA or 10K potentiometer or pre-set level). It accepts power supply voltages from 9 to 28VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The current output is 2A. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current, ramp times, dither frequency, and amplitude to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. Other versions are available with 4-20mA or 0-10V inputs. A remote mount version is housed in a rugged metal box.

 
Technical Specifications N/A Connector Amplifier For Proportional Valves P/N: CAPV-H-5V-x Complete with cable CAPV-6C-yM Where: x = maximum current output (2A, 1.2A, 800mA or 600mA) y = cable length (2 meters is the standard length)
Order Code N/A P/N: CAPV-H-5V-2A c/w CAPV-6C-2M N/A P/N: CAPV-H-5V-1.2A-6C-2M N/A P/N: CAPV-H-5V-800MA-6C-2M N/A P/N: CAPV-H-5V-600MA N/A P/N: CAPVH5V2A6C8M
Operating Voltage N/A 9 to 28 VDC Power Supply Range Accepts up to a maximum of 32 VDC
Protection N/A Reverse Polarity Protection Short circuit proof (in case of solenoid failure or miswiring)
Signal Inputs N/A 0-5 VDC voltage signal or
0-20 mA current signal or
10K Potentiometer (accepts 2.5K to 50K pots)
(4-20mA or 0-10VDC input versions are also available.)
For soft shift control, pre-set the connector amplifier by connecting +5VDC to input and using the Imax adjustment
N/A 0-5 VDC voltage signal or
0-20 mA current signal or
10K Potentiometer (accepts 2.5K to 50K pots)
(4-20mA or 0-10VDC input versions are also available.)
For soft shift control, pre-set the connector amplifier by connecting +5VDC to input and using the Imax adjustment
N/A 0-5 VDC voltage signal or
0-20 mA current signal or
10K Potentiometer (accepts 2.5K to 50K pots)
(4-20mA or 0-10VDC input versions are also available.)
For soft shift control, pre-set the connector amplifier by connecting +5VDC to input and using the Imax adjustment
N/A 0-5 VDC voltage signal or
0-20 mA current signal or
10K Potentiometer (accepts 2.5K to 50K pots)
(4-20mA or 0-10VDC input versions are also available.)
For soft shift control, pre-set the connector amplifier by connecting +5VDC to input and using the Imax adjustment
N/A 0-5 VDC voltage signal or
0-20 mA current signal or
10K Potentiometer (accepts 2.5K to 50K pots)
(4-20mA or 0-10VDC input versions are also available.)
For soft shift control, pre-set the connector amplifier by connecting +5VDC to input and using the Imax adjustment
Input Resistance N/A Current mode: 50 Ohms Voltage mode: 125K Ohms
Range of Maximum Output Current N/A 2A N/A 1.2A N/A 800mA N/A 600mA N/A 2A
Solenoid Resistance Selection (Nominal) N/A Nominal Resistance of Solenoid Coil should Comply with: Rcoil < (Vpower supply - 1.5 V)/I-max
Internal Supply for Setpoint Potentiometer N/A +5 VDC
Connections N/A DIN 43650 plug
2 meters jacketed cable, 6 conductor 18AWG
(A version for remote mounting is also available.)
N/A DIN 43650 plug
2 meters jacketed cable, 6 conductor 18AWG
(A version for remote mounting is also available.)
N/A DIN 43650 plug.
2 meters jacketed cable, 6 conductor 18AWG
(A version for remote mounting is also available.)
N/A DIN 43650 plug.
2 meters jacketed cable, 6 conductor 18AWG
(A version for remote mounting is also available.)
N/A DIN 43650 plug
8 meters jacketed cable, 6 conductor 18AWG
(A version for remote mounting is also available.)
Cable Length N/A 2 m N/A 2 m N/A 2 m N/A 2 m N/A 8 m
Protection Rating N/A IP65 when correctly installed with lid, compression washer, o-ring and base gasket.
Operating Temperature N/A -40 to 85 ºC-40 to 185 ºF
Approvals N/A CE Marking
Electromagnetic Compatibility (EMC) N/A Emission EN 50081-2 Immunity EN 50082-2
Applications N/A

Accurate control of hydraulic and pneumatic proportional solenoid valves used in mobile construction equipment and industrial processes.