The 4-20mA Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (4-20mA). It accepts 12VDC or 24VDC power supply voltage. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The options for maximum current output include 2 A, 1.2 A or 600mA. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current. Ramp time, dither frequency and amplitude can also be adjusted to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. It is also available with 0-10V or 0-5V inputs. A remote mount version is housed in a rugged metal box.
Items |
/Asset/CAPV-H-4-20MA-x--AX02030X.jpg CAPV-4-20MA-2A-4C-2M CAPV-4-20MA-2A-4C-2M Connector Amplifier, 4-20 mA Input, 2A Output, DIN 43650A, 2m Cable |
/Asset/CAPV-H-4-20MA-x--AX02030X.jpg CAPV-4-20MA-1.2A-4C-2M CAPV-4-20MA-1.2A-4C-2M Connector Amplifier, 4-20 mA Input, 1.2A Output, DIN 43650A, 2m Cable |
/Asset/CAPV-H-4-20MA-x--AX02030X.jpg CAPV-4-20MA-600MA-4C-2M CAPV-4-20MA-600MA-4C-2M Connector Amplifier, 4-20 mA Input, 600 mA Output, DIN 43650A, 2m Cable |
/Asset/CAPV-H-4-20MA-x--AX02030X.jpg CAPV-H-4-20MA-1.2A-S-4C CAPV-H-4-20MA-1.2A-S4C-7M Connector Amplifier, 4-20 mA Input, 1.2A Output, DIN 43650A, 7m Shielded Cable |
/Asset/CAPV-H-4-20MA-x--AX02030X.jpg CAPVH420MA12AS4C CAPV-H-4-20MA-1.2 A-S4C-7M Shielded Cable, Connector Amplifier |
|||||
Description |
N/A
The 4-20mA Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (4-20mA). It accepts 12VDC or 24VDC power supply voltage. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The maximum current output is 2A. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current. Ramp time, dither frequency and amplitude can also be adjusted to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. It is also available with 0-10V or 0-5V inputs. A remote mount version is housed in a rugged metal box. |
N/A
The 4-20mA Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (4-20mA). It accepts 12VDC or 24VDC power supply voltage. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The maximum current output is 1.2A. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current. Ramp time, dither frequency and amplitude can also be adjusted to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. It is also available with 0-10V or 0-5V inputs. A remote mount version is housed in a rugged metal box. |
N/A
The 4-20mA Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (4-20mA). It accepts 12VDC or 24VDC power supply voltage. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The maximum current output is 600mA. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current. Ramp time, dither frequency and amplitude can also be adjusted to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. It is also available with 0-10V or 0-5V inputs. A remote mount version is housed in a rugged metal box. |
N/A
The 4-20mA Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (4-20mA). It accepts 12VDC or 24VDC power supply voltage. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The maximum current output is 1.2A. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current. Ramp time, dither frequency and amplitude can also be adjusted to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. It is also available with 0-10V or 0-5V inputs. A remote mount version is housed in a rugged metal box. |
N/A
The 4-20mA Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (4-20mA). It accepts 12VDC or 24VDC power supply voltage. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The maximum current output is 1.2A. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current. Ramp time, dither frequency and amplitude can also be adjusted to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. It is also available with 0-10V or 0-5V inputs. A remote mount version is housed in a rugged metal box. |
|||||
Technical Specifications |
N/A
CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output (2A, 1.2A or 600MA) y = cable length (2 meters is the standard length) |
|||||||||
Order Code | N/A P/N: CAPV-4-20MA-2A-4C-2M | N/A P/N: CAPV-4-20MA-1.2A-4C-2M | N/A P/N: CAPV-4-20MA-600MA-4C-2M | N/A P/N: CAPV-H-4-20-MA-1.2A-S-4C | N/A P/N: CAPVH420MA12AS4C | |||||
Operating Voltage | N/A 12 or 24 VDC nominal | |||||||||
Protection |
N/A
Reverse Polarity Protection Short circuit proof (in case of solenoid failure or mis-wiring) |
|||||||||
Signal Inputs | N/A 4-20 mA Current Signal | |||||||||
Range of Maximum Output Current | N/A 2A | N/A 1.2A | N/A 600mA | N/A 1.2A | N/A 1.2A | |||||
Solenoid Resistance Selection (Nominal) | N/A Nominal Resistance of Solenoid Coil should Comply with: Rcoil < (Vpower supply - 1.5 V)/I-max | |||||||||
Connections |
N/A
DIN 43650-A 2 m, 4 conductor, unterminated cable (18 AWG) (Remote mount version with cable available). |
N/A
DIN 43650-A 2 m, 4 conductor, unterminated cable (18 AWG) (Remote mount version with cable available). |
N/A
DIN 43650-A. 2 m, 4 conductor, unterminated cable (18 AWG). (Remote mount version with cable available). |
N/A
DIN 43650-A. 2 m, 4 conductor, unterminated cable (18 AWG). (Remote mount version with cable available). |
N/A
DIN 43650-A. 2 m, 4 conductor, unterminated cable (18 AWG). (Remote mount version with cable available). |
|||||
Protection Rating | N/A IP65 when correctly installed with lid, o-ring/washer and base gasket. | |||||||||
Operating Temperature | N/A -40 to +85 ºC-40 to 185 ºF | N/A -40 to +85 ºC-40 to 185 ºF | N/A -40 to +85 ºC-40 to 185 ºF | N/A -40 to 85 ºC-40 to 185 ºF | N/A -40 to 85 ºC-40 to 185 ºF | |||||
Approvals | N/A CE Marking | |||||||||
Electromagnetic Compatibility (EMC) | N/A Emission EN 50081-2 Immunity EN 50082-2 | N/A Emission EN 50081-2 Emission EN 50082-2 | N/A Emission EN 50081-2 Immunity EN 50082-2 | N/A Emission EN 50081-2 Immunity EN 50082-2 | N/A Emission EN 50081-2 Immunity EN 50082-2 | |||||
Applications |
N/A
Accurate control of hydraulic and pneumatic proportional solenoid valves used in mobile construction equipment and industrial processes. |
|||||||||
|