PWM Converters
I/O Controls & Signal Converters
PWM Converters provide a compact solution for converting digital pulse width modulated (PWM) signal into current or current into PWM.
Unit of Measure
Items |
/Asset/IPWM-DR-200MA.gif PWMI-DR-200mA (PWM to 0-200mA) 8 Vdc, PWM Converter (Fully Isolated) |
/Asset/PWMI-DR-20MA.gif PWMI-DR-20mA (PWM to 0-20mA) PWM Converter (Fully Isolated) |
/Asset/IPWM-DR-200MA.gif IPWM-DR-200mA IPWM-DR-200MA Current to PWM Converter |
/Asset/PWMIWG8082x3.jpg PWMI-0000003 PWMI-WG8-08, PWM To 4-20mA Signal Converter, 100 mSec |
/Asset/PWMIWG8082x3.jpg PWMI-0000005 PWMI-WG8-06, PWM To 0-10V Signal Converter, 100 mSec. |
|||||
Description |
N/A
PWM Converters provide a compact solution for converting digital pulse width modulated (PWM) signal into current or current into PWM. |
|||||||||
Order Code | N/A P/N: PWMI-DR-200mA (PWM to 0-200mA) | N/A P/N: PWMI-DR-20mA (PWM to 0-20mA) | N/A P/N: IPWM-DR-200mA (0-200mA to PWM) | N/A P/N: PWMI-0000003 | N/A P/N: PWMI-0000005 | |||||
Operating Voltage | N/A 24VDC Nominal (15-45VDC) | N/A 24VDC Nominal (15-45VDC) | N/A 24VDC Nominal (15...45VDC) | N/A 24 VDC +/-10% | N/A 24 VDC +/-10% | |||||
Protection | N/A Reverse Polarity Protection Provided. Transient Protection Provided. | N/A Reverse Polarity Protection Provided. Transient Protection Provided. | N/A Reverse Polarity Protection Provided. Transient Protection Provided. | N/A Short circuit protection Transient Protection | N/A Short circuit protection Transient Protection | |||||
Voltage Input |
N/A
Low <1.5V High >3.5V (50V max.) TTL and CMOS Compatible |
N/A
Low <1.5V High >3.5V (50V max.) TTL and CMOS Compatible |
N/A
Low <1.5V High >3.5V (50V max.) TTL and CMOS Compatible |
N/A
Low <1.5V High >3.5V (50V max.) TTL and CMOS compatible |
N/A
Low <1.5V High >3.5V (50V max.) TTL and CMOS compatible |
|||||
Current Input | N/A | N/A | N/A Fully Isolated 0 - 200 mA | N/A 4 to 20 mA | N/A | |||||
Input Impedance | N/A 200 kOhms | N/A 200 kOhms | N/A 5 Ohms | N/A 200 kOhms | N/A 200 kOhms | |||||
PWM Input | N/A Fully Isolated PWM Frequency 60 Hz to 2 kHz, PWM Range 0-99% | N/A Fully Isolated PWM Frequency 60 Hz to 2 kHz, PWM Range 0-99% | N/A | N/A | N/A | |||||
Voltage Output | N/A | N/A | N/A | N/A 0.5 to 4.5 VDC | N/A 0 to 10 VDC | |||||
Output Voltage (Low) | N/A | N/A | N/A 0.3 Vdc or Less at 1 mA 0.7 Vdc or Less at 10 mA | N/A | N/A | |||||
Output Voltage (High) | N/A | N/A | N/A 30 Vdc or Less at <10 mA | N/A | N/A | |||||
PWM Output | N/A | N/A |
N/A
PWM 485 Hz +/- 10% 5-90% (Variable Active High) Open Collector Over-Current Protection |
N/A | N/A | |||||
Output Current | N/A 0-200 mA (PWMI-DR-200mA) Fully Isolated | N/A 0-20 mA (PWMI-DR-20mA) Fully Isolated | N/A | N/A 4-20 mA | N/A | |||||
Compliance Voltage Output | N/A 8 VDC | N/A 8 VDC | N/A | N/A 10VDC | N/A 6.5 VDC | |||||
Response Time Output | N/A <40 mSec. | N/A <40 mSec. | N/A <10 mSec. | N/A 100 mSec. | N/A 100 mSec. | |||||
Enclosure |
N/A
DR12, DIN Rail Mount, Polycarbonate 2.95 x 3.88 x 0.89 inches 75 x 98.5 x 22.5 mm (W x H x D) |
N/A
DR12, DIN Rail Mount, Polycarbonate 2.95 x 3.88 x 0.89 inches 75 x 98.5 x 22.5 mm (W x H x D) |
N/A
DR12, DIN Rail Mount, Polycarbonate 2.95 x 3.88 x 0.89 inches 75 x 98.5 x 22.5 mm (W x H x D) |
N/A
Housing (Wieland WEG8), Polyamide 6.6 plastic, UL94V-0, DIN rail mount 60.6 x 90.5 x 28.5 mm (W x H x D) 2.38 x 3.56 x 1.12 inches excluding DIN rail |
N/A
Housing (Wieland WEG8), Polyamide 6.6 plastic, UL94V-0, DIN rail mount 60.6 x 90.5 x 28.5 mm (W x H x D) 2.38 x 3.56 x 1.12 inches excluding DIN rail |
|||||
Connections | N/A #14-24 AWG Screw Terminals | N/A #14-24 AWG Screw Terminals | N/A #14-24 AWG Screw Terminals | N/A #12 to #22 AWG screw terminals | N/A #12 to #22 AWG screw terminals | |||||
Protection Rating | N/A IP20 Rated Terminals IP40 Rated Housing | N/A IP20 Rated Terminals IP40 Rated Housing |
N/A
IP20 Rated Terminals IP40 Rated Housing |
N/A IP20 | N/A IP20 | |||||
Operating Temperature | N/A 0 to 95% Relative Humidity -40 to 85 ºC-40 to 185 ºF | N/A 0 to 95% Relative Humidity -40 to 85 ºC-40 to 185 ºF | N/A 0 to 95% Relative Humidity -40 to 85 ºC-40 to 185 ºF | N/A -40 to 85 ºC-40 to 185 ºF | N/A -40 to 85 ºC-40 to 185 ºF | |||||
Adjustments |
N/A
Offset (Zero) and Span Trim Pots are 10 Turn CW = Increasing (Offset) CCW = Increasing (Span) Factory Settings: 0 mA (Offset) 200 mA or 20 mA (Span) |
N/A
Offset (Zero) and Span Trim Pots are 10 Turn CW = Increasing (Offset) CCW = Increasing (Span) Factory Settings: 0 mA (Offset) 200 mA or 20 mA (Span) |
N/A
Offset (Zero) and Span Trim Pots are 10 Turn CW = Increasing (Offset) CCW = Increasing (Span) Factory Settings: 0 mA (5% PWM) 200 mA (90% PWM) PWM Output can be Measured Using a Multi-meter (With a PWM Measurement Feature) |
N/A Span and Offset (Zero) | N/A Span and Offset (Zero) | |||||
Applications | N/A Industrial Controls Mobile Equipment | N/A Industrial Controls Mobile Equipment | N/A Industrial Controls Mobile Equipment |
N/A
Industrial and Machine Controls |
N/A
Industrial and Machine Controls |
|||||
|