Discrete I/O Modules with Relay Outputs and CAN From Axiomatic
The Discrete I/O Module reads 12 discrete inputs and sets 8 Form C relay outputs while networking with other CAN devices (SAE J1939 or CANopen®) in a machine control system. The unit is a battery powered device with the ability to withstand engine cranking, reverse polarity and transient power conditions. In engine applications, information is provided to the engine control system using single-frame J1939 or CANopen® application-specific PDU2 type messages. Outputs can be controlled by any input or CAN message. A bi-color LED indicates operational status.
The module has a number of setpoints that allow the user to configure it for their application. The Windows-based Electronic Assistant can be used to configure the module over the CAN J1939 line. The setpoints can also be saved to a file and flashed into other similar modules over the CAN bus. Alternatively, a RS-232 interface allows for quick user configuration adjustments using Windows HyperTerminal or other similar terminal software. Settings are saved to non-volatile memory upon command.
The unit features rugged packaging and watertight TE Deutsch connectors for an IP65 rating. The module is UL recognized for UL508 (FTPM2) – Controls for Stationary Engine Driven Assemblies and has a cUL recognition as well. The control carries a CE mark for the EMC and RoHS Directives. The DIO Module meets the environmental, EMC and vibration requirements of generator set applications in marine installations and, depending on the model, may have type approvals from several marine societies (LR, DNV-GL, ABS, RINA, CCS, and BV).
Model AX031800 is a new alternative to AXDIO128 or AXDIO128-03 and AX031850 features the same functionality in a compact enclosure.
CAN I-O Modules
Can I O Modules For Can Communication - can i/o module
Hydraulic analog canopen technology, sensor technology interface electronics. Peripheral device, solid state contactor, statistics, detector, electronic, waterproof, gateway, modular, analog, programming, ecan, software. Communication logic digital module relay canopen ethernet data.
can i/o module relay
Items |
/Asset/AX031800.jpg AX031800 12 Inputs, 8 Relay Outputs, SAE J1939, LED Indicator |
/Asset/AX031801.jpg AX031801 12 Inputs, 8 Relay Outputs, CANopen®, LED Indicator |
/Asset/AX031850.jpg AX031850 12 Inputs, 8 Relay Outputs, SAE J1939 250kbps |
/Asset/AX031850.jpg AX031850-01 12 Inputs, 8 Relay Outputs, SAE J1939 500 kbps |
/Asset/AX031850.jpg AX031850-02 12 Inputs, 8 Relay Outputs SAE J1939 1 Mbps |
|||||
Description |
N/A
The Discrete I/O Module reads 12 discrete inputs and sets 8 Form C relay outputs while networking with other CAN devices (SAE J1939) in a machine control system. The unit is a battery powered device with the ability to withstand engine cranking, reverse polarity and transient power conditions. In engine applications, information is provided to the engine control system using single-frame J1939 application-specific PDU2 type messages. Outputs can be controlled by any input or CAN message. A bi-color LED indicates operational status. |
N/A
The Discrete I/O Module reads 12 discrete inputs and sets 8 Form C relay outputs while networking with other CAN devices (CANopen®) in a machine or engine control system. The unit is a battery powered device with the ability to withstand engine cranking, reverse polarity and transient power conditions. Outputs can be controlled by any input or CAN message. A bi-color LED indicates operational status. |
N/A
The Discrete I/O Module reads 12 discrete inputs and sets 8 Form C relay outputs while networking with other CAN devices (SAE J1939) in a machine control system. The unit is a battery powered device with the ability to withstand engine cranking, reverse polarity and transient power conditions. In engine applications, information is provided to the engine control system using single-frame J1939 application-specific PDU2 type messages. Outputs can be controlled by any input or CAN message. A bi-color LED indicates operational status. |
N/A
The Discrete I/O Module reads 12 discrete inputs and sets 8 Form C relay outputs while networking with other CAN devices (SAE J1939) in a machine control system. The unit is a battery powered device with the ability to withstand engine cranking, reverse polarity and transient power conditions. In engine applications, information is provided to the engine control system using single-frame J1939 application-specific PDU2 type messages. Outputs can be controlled by any input or CAN message. A bi-color LED indicates operational status. |
N/A
The Discrete I/O Module reads 12 discrete inputs and sets 8 Form C relay outputs while networking with other CAN devices (SAE J1939) in a machine control system. The unit is a battery powered device with the ability to withstand engine cranking, reverse polarity and transient power conditions. In engine applications, information is provided to the engine control system using single-frame J1939 application-specific PDU2 type messages. Outputs can be controlled by any input or CAN message. A bi-color LED indicates operational status. |
|||||
Order Code | N/A P/N: AX031800 | N/A P/N: AX031801 | N/A P/N: AX031850 | N/A P/N: AX031850-01 | N/A P/N: AX031850-02 | |||||
Operating Voltage | N/A 12VDC or 24VDC nominal (9…32 VDC power supply range) | N/A 12V or 24VDC nominal (9…32 VDC power supply range) | N/A 12V or 24VDC nominal (9…32 VDC power supply range) | N/A 12V or 24VDC nominal (9…32 VDC power supply range) | N/A 12V or 24VDC nominal (9…32 VDC power supply range) | |||||
Inputs |
N/A
Reads twelve (12) discrete inputs (active low with pull-up resistors): Low-Level input voltage: 0 to 0.8 V. High-Level Input Voltage: 3.75 to +BAT Input resistance: more than 5 kOhms. Inputs have internal pull-up resistors. The inputs have internal over and under voltage protection. |
N/A
Reads twelve (12) discrete inputs (active low with pull-up resistors): Low-Level input voltage: 0 to 0.8 V High-Level Input Voltage: 3.75 to +BAT Inputs have internal pull-up resistors. Input resistance: more than 5 kOhms. The inputs have internal over and under voltage protection. |
N/A
Reads twelve (12) discrete inputs (active low with pull-up resistors): Low-Level input voltage: 0 to 0.8 V High-Level Input Voltage: 3.75 to +BAT Inputs have internal pull-up resistors. Input resistance: more than 5 kOhms. The inputs have internal over and under voltage protection. |
N/A
Reads twelve (12) discrete inputs (active low with pull-up resistors): Low-Level input voltage: 0 to 0.8 V High-Level Input Voltage: 3.75 to +BAT Inputs have internal pull-up resistors. Input resistance: more than 5 kOhms. The inputs have internal over and under voltage protection. |
N/A
Reads twelve (12) discrete inputs (active low with pull-up resistors): Low-Level input voltage: 0 to 0.8 V High-Level Input Voltage: 3.75 to +BAT Inputs have internal pull-up resistors. Input resistance: more than 5 kOhms. The inputs have internal over and under voltage protection. |
|||||
Outputs |
N/A
Sets 8 Form C relay outputs Resistive load: 2A (NO)/2 A (NC) at 277 VAC 2 A (NO)/2 A (NC) at 30 VDC 2 A (NO)/2 A (NC) at 125 VAC |
N/A
Sets 8 Form C relay outputs. Resistive load: 2A (NO)/2 A (NC) at 277 VAC 2 A (NO)/2 A (NC) at 125 VAC 2 A (NO)/2 A (NC) at 30 VDC |
N/A
Sets 8 Form C relay outputs. Resistive load: 2A (NO)/2 A (NC) at 277 VAC 2 A (NO)/2 A (NC) at 125 VAC 2 A (NO)/2 A (NC) at 30 VDC |
N/A
Sets 8 Form C relay outputs. Resistive load: 2A (NO)/2 A (NC) at 277 VAC 2 A (NO)/2 A (NC) at 125 VAC 2 A (NO)/2 A (NC) at 30 VDC |
N/A
Sets 8 Form C relay outputs. Resistive load: 2A (NO)/2 A (NC) at 277 VAC 2 A (NO)/2 A (NC) at 125 VAC 2 A (NO)/2 A (NC) at 30 VDC |
|||||
Relay Output | N/A Relay (8) | |||||||||
Communications | N/A 1 CAN 2.0B port, protocol SAE J1939 | N/A 1 CAN 2.0B port, protocol CANopen® | N/A 1 CAN 2.0B port, protocol SAE J1939 | N/A 1 CAN 2.0B port, protocol SAE J1939 | N/A 1 CAN 2.0B port, protocol SAE J1939 | |||||
CAN Baud Rate | N/A 250 kbps | N/A Selectable | N/A 250 kbps | N/A 500 kbps | N/A 1 Mbps | |||||
Control Logic | N/A Designed to work either as a stand-alone module, or on a J1939 CAN network. When connected to the network, it automatically recognizes network connection, claims a network address and can be configured to perform application tasks. User programmable functionality using Electronic Assistant. | N/A An EDS File is provided. Standard embedded control logic is provided. User programmable functionality uses SDO object access, per CiA DS-301 with commercially available CANopen® tools. | N/A Designed to work either as a stand-alone module, or on a J1939 CAN network. When connected to the network, it automatically recognizes network connection, claims a network address and can be configured to perform application tasks. User programmable functionality using Electronic Assistant. | N/A Designed to work either as a stand-alone module, or on a J1939 CAN network. When connected to the network, it automatically recognizes network connection, claims a network address and can be configured to perform application tasks. User programmable functionality using Electronic Assistant. | N/A Designed to work either as a stand-alone module, or on a J1939 CAN network. When connected to the network, it automatically recognizes network connection, claims a network address and can be configured to perform application tasks. User programmable functionality using Electronic Assistant. | |||||
Enclosure |
N/A
Rugged aluminum housing, stainless steel end plates, neoprene gaskets 145.30 x 149.00 x 73.00 mm (5.72 x 5.86 x 2.87 inches) L x W x H |
N/A
Rugged aluminum housing, stainless steel end plates, neoprene gaskets. 145.30 x 149.00 x 73.00 mm (5.72 x 5.86 x 2.87 inches) L x W x H |
N/A
CINCH 40-pin receptacle P/N: 5810140011 95 x 130 x 42 mm (3.73 x 5.13 x 1.67”) L x W x H CINCH mini-ME enclosure P/N: 5810130090 Polyphthalamide (PPS) plastic resin, UR, Flammability Rating HB |
N/A
CINCH 40-pin receptacle P/N: 5810140011 95 x 130 x 42 mm (3.73 x 5.13 x 1.67”) L x W x H CINCH mini-ME enclosure P/N: 5810130090 Polyphthalamide (PPS) plastic resin, UR, Flammability Rating HB |
N/A
CINCH 40-pin receptacle P/N: 5810140011 95 x 130 x 42 mm (3.73 x 5.13 x 1.67”) L x W x H CINCH mini-ME enclosure P/N: 5810130090 Polyphthalamide (PPS) plastic resin, UR, Flammability Rating HB |
|||||
Protection Rating | N/A IP67, Pollution Degree 3 Rating per UL508 | N/A IP67, Pollution Degree 3 Rating per UL509 | N/A IP67, Pollution Degree 3 Rating per UL508 | N/A IP67, Pollution Degree 3 Rating per UL508 | N/A IP67, Pollution Degree 3 Rating per UL508 | |||||
Compliance | N/A CE Marking for EMC and RoHS Directives Marine Type Approvals: Lloyd’s Register TAC, CCS TAC, ABS PDA, RINA REACH-SVHC UL508 (April 2010) (FTPM2) – Controls for Stationary Engine Driven Assemblies and cUL C22.2 No. 14-10 (2010) | N/A CE Marking for EMC and RoHS Directives UL508 (April 2010) (FTPM2) – Controls for Stationary Engine Driven Assemblies and cUL C22.2 No. 14-10 (2010) | N/A CE Marking for EMC and RoHS Directives UL508 (April 2010) (FTPM2) – Controls for Stationary Engine Driven Assemblies and cUL C22.2 No. 14-10 (2010) | N/A CE Marking for EMC and RoHS Directives UL508 (April 2010) (FTPM2) – Controls for Stationary Engine Driven Assemblies and cUL C22.2 No. 14-10 (2010) | N/A CE Marking for EMC and RoHS Directives UL508 (April 2010) (FTPM2) – Controls for Stationary Engine Driven Assemblies and cUL C22.2 No. 14-10 (2010) | |||||
Applications |
N/A
AX070200, Plug Kit: DT06-08A, W8S, sockets + DRC16-40S (no key), sockets |
N/A
Power Generator Sets |
N/A
Power Generator Sets |
N/A
AX070147, Mating Plug Kit (Molex 33472-2001 (Key A), Molex 33472-2002 (Key B), 40 Crimp Terminals, 6 Cavity Plugs) |
N/A
Item# - AX070147 |
|||||
Fieldbus | N/A SAE J1939 | N/A CANopen | N/A SAE J1939 | N/A SAE J1939 | N/A SAE J1939 | |||||
Isolation | N/A CAN | |||||||||
Digital | N/A Discrete (12) | |||||||||
Marks | N/A CE / UKCA Marking for EMC and RoHS Directives | N/A CE pending | N/A CE pending | N/A CE pending | N/A CE pending | |||||
Accessories |
N/A
AX070200, Plug Kit: DT06-08A, W8S, sockets + DRC16-40S (no key), sockets AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions) |
N/A
AX070200, Plug Kit: DT06-08A, W8S, sockets + DRC16-40S (no key), sockets |
N/A
AX070147, Mating Plug Kit (Molex 33472-2001 (Key A), Molex 33472-2002 (Key B), 40 Crimp Terminals, 6 Cavity Plugs) AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions) |
N/A
AX070147, Mating Plug Kit (Molex 33472-2001 (Key A), Molex 33472-2002 (Key B), 40 Crimp Terminals, 6 Cavity Plugs) AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions) |
N/A
AX070147, Mating Plug Kit (Molex 33472-2001 (Key A), Molex 33472-2002 (Key B), 40 Crimp Terminals, 6 Cavity Plugs) AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions) |
|||||
EDS | N/A |
N/A
EDS-AX031801 |
N/A | N/A | N/A | |||||
|