Print Back

The controller features 1 CAN port for controlling the outputs and diagnostics over the SAE J1939 CAN bus. It accepts a nominal input power supply voltage of 12Vdc or 24Vdc. Using the CAN network, it can provide control of up to ten outputs, configured for a wide variety of responses and up to 2.5A per channel (max 7A per module). For example, it can drive proportional valves, on/off valves or provide a hotshot control profile. PWM signal or proportional voltage outputs are also user selectable. Standard software is provided. The sophisticated microprocessor can accommodate complex application-specific control algorithms for advanced machine control on request. Rugged packaging and power supply surge protection suits the harsh environment of mobile equipment with on-board battery power. Settings are user configurable via a Windows-based Electronic Assistant configuration tool interfacing to the controller via an USB-CAN device.

Unit of Measure

Specifications

Technical Specifications

N/A CAN to 10 Output Valve Controller, SAE J1939

Order Code

N/A P/N: AX021210

Operating Voltage

N/A 12Vdc or 24Vdc nominal (9…40Vdc)
NB. The maximum total current draw permitted on the power supply input pins is 7 Amps @ 24VDC, at one time.

Protection

N/A Surge and transient protection
Reverse polarity protection
Over-voltage protection
Under-voltage protection

Outputs

N/A 10 universal outputs of up to 2.5A are user selectable from the following types:
Output Disabled
Hotshot Digital On/Off Digital Proportional Current Proportional Voltage PWM Duty Cycle

Communications

N/A 1 CAN port (2.0B, SAE J1939)

Control Logic

N/A Standard embedded control logic is provided.
User programmable functionality using Electronic Assistant.
(Application specific setpoints or firmware is available on request.)

Enclosure

N/A High Temperature Nylon housing
TE Deutsch PCB Enclosure (EEC-325X4B)
4.62 x 5.24 x 1.43 inches
117.42 x 133.09 x 36.36 mm
(W x L x H excluding mating plugs)

Protection Rating

N/A IP67

Operating Temperature

N/A -40 to 85 ºC-40 to 185 ºF

Applications

N/A

Municipal Vehicles
Off-highway Construction Equipment

Accessories

Accessories

N/A AX070502, Axiomatic Electronic Assistant KIT (USB-CAN Converter, USB-A to USB-B Cable, CAN Cable, Installation Instructions)
PL-DTM06-12SA-12SB, Mating Plug KIT (DTM06-12SA, DTM06-12SB, 2 WM12S, 24 Contacts, Plugs)