The CAN-PWM Signal Converter features PWM Signal output to communicate with an engine ECM; output is user configurable as Frequency or digital. This product meets the surge requirements of SAE J1445, and is designed for EMC compliance, and is configurable with Axiomatic Electronic Assistant.
Technical Specifications |
N/A CAN to PWM Signal Controller, SAE J1939 |
Order Code |
N/A P/N: AX130700AB |
Operating Voltage |
N/A 12 Vdc or 24 Vdc Nominal |
Outputs |
N/A
Digital Level Digital On/Off 5V or 12V amplitude Maximum load is 50mA (at 5V) or 30mA (at 12V) PWM Signal, Frequency Signal or Mixed Output: 1 Hz to 20 kHz 0 to 100% DC (user configurable) 5V or 12V amplitude Push pull output Maximum load is 50 mA (at 5V) or 30 mA (at 12 V) Overcurrent protection |
Communications |
N/A 1 CAN (SAE J1939 with Auto-Baud-Rate-Detection) |
Control Logic |
N/A The CAN-PWM Signal Converter comes pre-programmed with standard logic. User configurable functionality using Electronic Assistant (P/N: AX070502). |
Enclosure |
N/A
Plastic Enclosure, Nylon 6-6 with 30% glass fill. Integral TE Deutsch Connector 3.030 x 2.413 x 1.314 Inches 77.0 x 61.3 x 33.4 mm (L X W X H) |
Connections |
N/A 6 pin TE Deutsch connector P/N: DT04-6P. |
Protection Rating |
N/A IP67 |
Operating Temperature |
N/A -40 to 85 ºC-40 to 185 ºF |
Applications |
N/A
Off-Highway Equipment Controls |
Datasheet |
N/A
TDAX130700AB |
User Manual |
N/A
AX130700 User Manual |
2D Drawing |
N/A
AX130700-2D |
STEP Files (3D) |
N/A
AX130700 |
Compliance |
N/A
EMC - DoC - AX1307XX LVD - DoC - All RoHS - DoC - All |