Print Back

The Dual Solenoid Multifunction Valve Driver provides accurate control of hydraulic proportional and directional valves used in mobile equipment and industrial processes, with input from a joystick, potentiometer or control system interface. This multifunctional design will support inputs from a joystick potentiometer with or without center tap, a standard potentiometer or commonly available control signals such as 0 to 5 Volts, 0 to +/-5 Volts, 0 to 10 Volts, 0 to +/-10 Volts, 0 to 20 mA, and 0 to +/-20 mA. The power supply connection is conditioned to withstand the harsh environment found in vehicular power systems. Maximum current output is adjustable from 0 to 2 Amps (300 mA and 100 mA output versions are available). A high low range input provides reduced output for limited operation. The driver is potted and packaged driver in a metal base.

 
Unit of Measure

Specifications

Order Code

N/A P/N: DSDA-SMB-SC-01 (standard input, 0 to 2 Amp max. output, screw terminals)

Operating Voltage

N/A 9 to 32 VDC Power Supply Range Total current draw will be the sum of the currents drawn by all connected equipment plus 25 mA.

Signal Inputs

N/A Current:
0 to 20 mA (10mA=0, +/-10mA)
0 to +/-20 mA (0mA=0, +/-20mA)
(User selectable by DIP switch SW2)
Voltage: 0 to 5 Volts (2.5V=0, +/-2.5V)
0 to +/-10 Volts (0V=0, +/-10V)
0 to +/-5 Volts (0V=0, +/-5V)
0 to 10 Volts (5V=0, +/-5V)
(User Selectable by DIP Switch SW1)
Other signal inputs are available. Contact manufacturer.

Potentiometer Input

N/A The potentiometer connection provides a 5.0 VDC bias voltage as well as a 2.5 VDC center-tap driving voltage. A remote joystick potentiometer with or without center tap may be used. A 10K potentiometer is recommended. The unit accepts pots from 5K to 50K Ohms. A 1K pot input version is available.

Low Range Input (Imax/2)

N/A This input, when active, will provide a 50% reduction in output current slope. It is used to increase the resolution of operation for limited operation such as when training new operators or during operation in tight quarters. Will activate by applying power (+ 9-32 VDC) to the Imax/2 tab and if not used, it may be left unconnected.

Input Resistance

N/A Current mode: 250 Ohms Voltage mode: 500 K Ohms

Range of Maximum Output Current

N/A 2000 mA Maximum output current is limited to 2.5A (min. current setting + max. current setting <2.5A).

Minimum Current Setting (Solenoid A and B)

N/A 0 to 2.0A (Adjustable)

Maximum Current Setting (Solenoid A and B)

N/A 0 to 2.0A (Adjustable) The Maximum Current is Offset by the Minimum Current Setting

Current Dither Frequency

N/A 70 to 350 Hz ±10% of Full Scale (Adjustable)

Dither Amplitude

N/A 0 to 10% of maximum current (Adjustable)

Dither Waveform

N/A Triangular

Current Ramp Time - Up and Down (Solenoid A and B)

N/A 0.01 - 5 Seconds Symmetrical/Non-symmetrical user Selectable by DIP Switch 2

Solenoid Resistance Selection (Nominal)

N/A Rcoil < (Vpower supply - 1.5 V)/I-max

Dimensions

N/A Potted Unit Packaged in a Metal Base
3.87 x 5.37 x 1.17 inches or 98.4 x 136.5 x 29.7 mm (W x L x H)

Connections

N/A Potted Driver:
Connection style - 22 flat tabs or screw terminals (complete with mating vertical plug-in terminals)
Tab connection version mates with 0.25 inch female tab connector, supplied by customer (Keystone P/N: 4470) and accepts 16-20 AWG wire (Other connection styles are available to meet OEM requirements.)

Protection Rating

N/A IP65 Rating Potted

Operating Temperature

N/A -40 to 85 ºC-40 to 185 ºF

Applications

N/A The Dual Solenoid Driver controls a variety of hydraulic valve combinations

Product Documents

Datasheet

N/A DSDA-X Datasheet

2D Drawing

N/A DSDA-SMB-SC-2D

STEP Files (3D)

N/A DSDA-SMB-SC-01-2A Screw Terminals

Compliance

N/A DSDA EMC
LVD - DoC - All
RoHS - DoC - All