Print Back

This protocol converter acts as a gateway or interface between CAN buses with different baud rates and protocols (SAE J1939-CANopen®). It also facilitates fast data exchange between a CAN network (SAE J1939 or CANopen®) and an RS-422/ RS-485 bus (Modbus RTU). This IP67 rated unit has a fully sealed enclosure that can withstand harsh environments.

Specifications

Order Code

N/A P/N: AX140321

Operating Voltage

N/A 12 VDC or 24 VDC Nominal (9...36 VDC)

Protection

N/A Reverse Polarity Protection is Provided Surge Protection @ 95 Vdc

Isolation

N/A 300 Vrms

CAN

N/A 2 Isolated CAN 2.0B
1 CANopen®, 1 SAE J1939 (10 kbit/s, 50 kbit/s, 100 kbit/s, 125 kbit/s, 250 kbit/s, 500 kbit/s, 1 Mbit/s Automatic Baud Rate Detection)

Communications

N/A 1 CANopen® 1 Non-isolated RS-422
AX140321 supports RS-485 if TX+ and RX+ (pins 10 & 8) are connected together (RS485 D+) and TX- and RX- (pins 9 & 4) are connected together (RS485 D-).
1 SAE J1939 (10 kbit/s, 50 kbit/s, 100 kbit/s, 125 kbit/s, 250 kbit/s, 500 kbit/s, 1 Mbit/s Auto-Baud-Rate Detection)

Enclosure

N/A Molded Enclosure, integral connector
Nylon 6/6, 30% glass
Ultrasonically welded
3.54 x 2.75 x 1.31 inches (90.09 x 70.00 x 33.35 mm)
L x W x H including integral connector

Protection Rating

N/A IP67

Connections

N/A 12 pin TE Deutsch style connector P/N: DT15-12PA

Marks

N/A Compliant to the EMC Directive Compliant to the RoHS Directive

Product Documents

Datasheet

N/A AX140321 Datasheet

User Manual

N/A AX140X00 User Manual

EDS

N/A AX140321 EDS

2D Drawing

N/A AX140321-MD-A

STEP Files (3D)

N/A 12-Pin Laser Welded Assembly

Compliance

N/A EMC - DoC - AX14032XX
LVD - DoC - All
RoHS - DoC - All

Accessories

Accessories

N/A AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions)
PL-DTM06-12SA, Mating Plug KIT (1-12 Socket)