Print Back

The Discrete I/O Module reads 12 discrete inputs and sets 8 Form C relay outputs while networking with other CAN devices (SAE J1939) in a machine control system. The unit is a battery powered device with the ability to withstand engine cranking, reverse polarity and transient power conditions. In engine applications, information is provided to the engine control system using single-frame J1939 application-specific PDU2 type messages. Outputs can be controlled by any input or CAN message. A bi-color LED indicates operational status.

Unit of Measure

Specifications

Order Code

N/A P/N: AX031850-02

Operating Voltage

N/A 12V or 24VDC nominal (9…32 VDC power supply range)

Communications

N/A 1 CAN 2.0B port, protocol SAE J1939

Control Logic

N/A Designed to work either as a stand-alone module, or on a J1939 CAN network. When connected to the network, it automatically recognizes network connection, claims a network address and can be configured to perform application tasks. User programmable functionality using Electronic Assistant.

Enclosure

N/A CINCH 40-pin receptacle P/N: 5810140011
95 x 130 x 42 mm
(3.73 x 5.13 x 1.67”)
L x W x H
CINCH mini-ME enclosure P/N: 5810130090
Polyphthalamide (PPS) plastic resin, UR, Flammability Rating HB

Protection Rating

N/A IP67, Pollution Degree 3 Rating per UL508

Operating Temperature

N/A -40 to 85 ºC-40 to 185 ºF

Outputs

N/A Sets 8 Form C relay outputs.
Resistive load:
2A (NO)/2 A (NC) at 277 VAC
2 A (NO)/2 A (NC) at 125 VAC
2 A (NO)/2 A (NC) at 30 VDC

Applications

N/A

Item# - AX070147
Item Name - Mating Plug Kit

Inputs

N/A Reads twelve (12) discrete inputs (active low with pull-up resistors):
Low-Level input voltage: 0 to 0.8 V
High-Level Input Voltage: 3.75 to +BAT
Inputs have internal pull-up resistors.
Input resistance: more than 5 kOhms.
The inputs have internal over and under voltage protection.

Isolation

N/A CAN

Relay Output

N/A Relay (8)

Marks

N/A CE pending

Digital

N/A Discrete (12)

CAN Baud Rate

N/A 1 Mbps

Fieldbus

N/A SAE J1939

# Inputs

N/A 12

# Outputs

N/A 8

# of Connections

N/A 40

Power (Vdc)

N/A 12 V24 V

Enclosure (Filter)

N/A Box

Compliance

N/A CE Marking for EMC and RoHS Directives UL508 (April 2010) (FTPM2) – Controls for Stationary Engine Driven Assemblies and cUL C22.2 No. 14-10 (2010)

Product Documents

Datasheet

N/A AX031850 Datasheet

User Manual

N/A AX0318x0 User Manual

2D Drawing

N/A AX031850-MD

STEP Files (3D)

N/A AX031850

Compliance

N/A EMC - DoC - AX1307XX
LVD - DoC - All
RoHS - DoC - All

Accessories

Accessories

N/A AX070147, Mating Plug Kit (Molex 33472-2001 (Key A), Molex 33472-2002 (Key B), 40 Crimp Terminals, 6 Cavity Plugs)
AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions)