These are legacy products.
Items |
AX020400A 12 Input, 12 Output Valve Controller, SAE J1939 |
AX020410A 12 Input, 12 Output Valve Controller, SAE J1939, Extended Functionality |
AX020411A 12 Input, 12 Output Valve Controller, CANopen®, Extended Functionality |
AX020507 Quad Valve Controller, SAEJ1939, 50mA +5Vref |
AX023220 2 Input, Dual Valve Controller, SAE J1939, High Temperature |
|||||
Description |
N/A
The valve controller drives 8 proportional or on/off solenoids plus 4 on/off solenoids. It is networked on a SAE J1939 bus. Up to 7 signal inputs and 5 digital inputs are accepted for interface to a PLC, Engine Control Module, switches, command potentiometers or sensors. It operates with 12Vdc or 24Vdc power. Designed for rugged machine applications, it features an IP67 rating and is suitable for high vibration installations. Controller settings are user configurable to suit many applications. |
N/A
The valve controller drives 8 proportional or on/off solenoids plus 4 on/off solenoids. It is networked on a SAE J1939 bus. Up to 7 signal inputs and 5 digital inputs are accepted for interface to a PLC, Engine Control Module, switches, command potentiometers or sensors. It operates with 12Vdc or 24Vdc power. Designed for rugged machine applications, it features an IP67 rating and is suitable for high vibration installations. Controller settings are user configurable to suit many applications. |
N/A
The valve controller drives 8 proportional or on/off solenoids plus 4 on/off solenoids. It is networked on a CANopen® bus. Up to 7 signal inputs and 5 digital inputs are accepted for interface to a PLC, Engine Control Module, switches, command potentiometers or sensors. It operates with 12Vdc or 24Vdc power. Designed for rugged machine applications, it features an IP67 rating and is suitable for high vibration installations. Controller settings are user configurable to suit many applications. |
N/A
The quad valve controller provides precise, repeatable control of 4 proportional solenoids and 1 on/off solenoid over an SAE J1939 network. It interfaces to a joystick or other command input to drive multiple hydraulic valves in off-highway machines. The electronic control can interface to an ECM for auxiliary electro-hydraulic control functions on mobile equipment. |
N/A
The dual input, dual output valve controller is designed for extremely versatile control of up to two proportional outputs to directly drive coils or other loads. Its flexible circuit design gives the user a wide range of configurable input or output types. The controller is a highly programmable controller, allowing the user to configure it for their application. Its sophisticated control algorithms allow for open or closed loop drive of the proportional outputs. It can be operated as either a self-contained control system, driving the outputs directly from the on-board inputs, and/or it can be integrated into a SAE J1939 network of controllers. |
|||||
Technical Specifications | N/A 12 Inputs, 12 Outputs Valve Controller, SAE J1939 | N/A 12 Inputs, 12 Outputs Valve Controller, SAE J1939 | N/A 12 Inputs, 12 Outputs Valve Controller, SAE J1939 | N/A Quad Controller, 50 mA +5V Ref (SAE J1939) | N/A 2 Universal Inputs, Dual Output Valve Controller, SAE J1939 | |||||
Order Code | N/A P/N: AX020400A (SAE J1939) | N/A P/N: AX020410A (SAE J1939) | N/A P/N: AX020411A (CANopen®) | N/A P/N: AX020507 | N/A P/N: AX023220 | |||||
Operating Voltage | N/A 12 Vdc or 24 Vdc Nominal | N/A 12 Vdc or 24 Vdc Nominal | N/A 12 Vdc or 24 Vdc Nominal |
N/A
8…36VDC 2 +5V, 50 mA |
N/A 12VDC or 24VDC nominal (9...60 VDC) | |||||
Isolation | N/A | |||||||||
Inputs |
N/A
1 Signal Input is user configurable as: 0-5V, 0-10V, 4-20mA or 0-20mA 1 Hz to 10 kHz PWM Digital 5 PWM/Digital Inputs are user configurable as: 1 Hz to 10 kHz PWM Active High/Active Low Digital 6 Universal Signal Inputs are user configurable as: 0-5V, 0-10V, 4-20mA or 0-20mA 20Ω to 250 kΩ Resistive 1 Hz to 10 kHz PWM Digital |
N/A
1 Signal Input is user configurable as: 0-5V, 0-10V, 4-20mA or 0-20mA 1 Hz to 10 kHz PWM Digital 5 PWM/Digital Inputs are user configurable as: 1 Hz to 10 kHz PWM Active High/Active Low Digital 6 Universal Signal Inputs are user configurable as: 0-5V, 0-10V, 4-20mA or 0-20mA 20Ω to 250 kΩ Resistive 1 Hz to 10 kHz PWM Digital |
N/A
1 Signal Input is user configurable as: 0-5V, 0-10V, 4-20mA or 0-20mA 1 Hz to 10 kHz PWM Digital 5 PWM/Digital Inputs are user configurable as: 1 Hz to 10 kHz PWM Active High/Active Low Digital 6 Universal Signal Inputs are user configurable as: 0-5V, 0-10V, 4-20mA or 0-20mA 20Ω to 250 kΩ Resistive 1 Hz to 10 kHz PWM Digital |
N/A
Up to 6 inputs, selectable from the following: 2 PWM signal (50Hz to 10kHz) Pulse 6 Digital 4 Analog (0-5V, 0-10V, 0-20 mA or 4-20 mA) |
N/A
2 universal signal inputs configurable as: Voltage Current Digital Encoder Frequency/RPM PWM Duty Cycle Resistive |
|||||
Outputs |
N/A
4 Outputs (3A) to drive ON/OFF hydraulic valves 8 Outputs (0…2.5A) are user selectable as: Proportional Current Hotshot Digital PWM Duty Cycle Proportional Voltage On/Off Digital |
N/A
4 Outputs (3A) to drive ON/OFF hydraulic valves 8 Outputs (0…2.5A) are user selectable as: Proportional Current Hotshot Digital PWM Duty Cycle Proportional Voltage On/Off Digital |
N/A
4 Outputs (3A) to drive ON/OFF hydraulic valves 8 Outputs (0…2.5A) are user selectable as: Proportional Current Hotshot Digital PWM Duty Cycle Proportional Voltage On/Off Digital |
N/A 1 on/off (up to 5A) 4 proportional (1.5A if all 4 used, or 2A for less than 4 used) |
N/A
2 outputs configurable as: Proportional Current Hotshot Digital On/Off Digital Proportional PWM Proportional Voltage |
|||||
CAN | N/A | |||||||||
Communications | N/A 1 Isolated CAN port (SAE J1939) | N/A 1 Isolated CAN port (SAE J1939) | N/A 1 Isolated CAN port (CANopen®) | N/A With SAE J1939 | N/A 1 CAN port (2.0B, SAE J1939) Check datasheet for baud rate options. | |||||
Control Logic | N/A Electronic Assistant (EA) AX070502 Standard embedded software is provided. | N/A Electronic Assistant (EA) AX070502 Standard embedded software is provided. | N/A EDS File Standard embedded software is provided. | N/A Standard embedded software with user selectable setpoints and control options (Refer to datasheet). |
N/A
User configurable functionality using the Electronic Assistant® service tool Refer to the User Manual for details. |
|||||
Enclosure |
N/A
High Temperature Nylon Housing, TE Deutsch IPD P/N: EEC-5X650B 4.03 x 4.25 x 1.68 inches 102.44 x 107.96 x 42.67 mm L x W x H Including Integral Connectors |
N/A
High Temperature Nylon Housing, TE Deutsch IPD P/N: EEC-5X650B 4.03 x 4.25 x 1.68 inches 102.44 x 107.96 x 42.67 mm L x W x H Including Integral Connectors |
N/A
High Temperature Nylon Housing, TE Deutsch IPD P/N: EEC-5X650B 4.03 x 4.25 x 1.68 inches 102.44 x 107.96 x 42.67 mm L x W x H Including Integral Connectors |
N/A
High Temperature Nylon Housing TE Deutcsh PCB Enclosure (EEC-325X4B) 24-pin Connector 4.62 x 5.24 x 1.43 inches 117.42 x 133.09 x 36.36 mm (W x L x H Excluding Mating Plug) |
N/A
High Temperature Nylon Housing TE Deutsch PCB Enclosure (EEC-325X4B) 4.62 x 5.24 x 1.43 Inches 117.42 x 133.09 x 36.36 mm (W x L x H excluding mating plugs) |
|||||
Protection Rating | N/A IP67 | N/A IP67 | N/A IP67 | N/A | N/A IP67 | |||||
Operating Temperature | N/A -40 to 85 ºC-40 to 185 ºF | N/A -40 to 85 ºC-40 to 185 ºF | N/A -40 to 85 ºC-40 to 185 ºF | N/A -40 to 85 ºC-40 to 185 ºF | N/A -40 to 125 ºC-40 to 257 ºF | |||||
Applications |
N/A
Industrial, off-highway (mobile) and marine applications for the control of hydraulic valves. |
N/A
Industrial, off-highway (mobile) and marine applications for the control of hydraulic valves. |
N/A
Industrial, off-highway (mobile) and marine applications for the control of hydraulic valves. |
N/A
Industrial, off-highway (mobile) and marine applications for control of hydraulic proportional poppet or spool valves |
N/A
The controller is designed to meet the rugged demands of mobile equipment, marine and heavy duty industrial machine applications. These applications include, but are not limited to:
|
|||||
Datasheet |
N/A
AX020400A Datasheet |
N/A
AX020410A Datasheet |
N/A
AX020411A Datasheet |
N/A
AX020507 Datasheet |
N/A
AX023220 Datasheet |
|||||
User Manual |
N/A
AX0204x0A User Manual |
N/A
AX0204x0A User Manual |
N/A
AX020411A User Manual |
N/A
AX020507 User Manual |
N/A
AX023220 User Manual |
|||||
2D Drawing |
N/A
AX020400-2D |
N/A
AX020410-2D |
N/A
AX020411A-2D |
N/A |
N/A
AX023220-MD-A |
|||||
STEP Files (3D) |
N/A
TEDeutsch48pinEnclosure |
N/A
TEDeutsch48pinEnclosure |
N/A
TEDeutsch48pinEnclosure |
N/A
TEDeutsch24pinEnclosure |
N/A
TEDeutsch12pinenclosure |
|||||
Compliance |
N/A
AX020400-2D LVD - DoC - All RoHS - DoC - All |
N/A
EMC - DoC - AX020400 LVD - DoC - All RoHS - DoC - All |
N/A
EMC - DoC - AX020400 LVD - DoC - All RoHS - DoC - All |
N/A
EMC - DoC - AX02050X LVD - DoC - All RoHS - DoC - All |
N/A
DOC-EMC-AX0232XX LVD - DoC - All RoHS - DoC - All UKCA - DoC - AX0232XX |
|||||
Reverse Polarity Protection | N/A | |||||||||
Thermocouple Inputs | N/A | |||||||||
Compliance | N/A | |||||||||
EDS | N/A | N/A |
N/A
EDS-AX020411A |
N/A | N/A | |||||
User Configurability | N/A | N/A | N/A | N/A Electronic Assistant, P/N: AX070502 | N/A | |||||
Reference Voltage | N/A | |||||||||
Current Input | N/A | |||||||||
Input Impedance | N/A | |||||||||
Response Time Output | N/A | |||||||||
Output Current | N/A | |||||||||
Output Impedance | N/A | |||||||||
Adjustments | N/A | |||||||||
Short Circuit Protection | N/A | |||||||||
Regulated Current Output | N/A | |||||||||
LED Outputs | N/A | N/A | N/A | N/A | N/A None | |||||
Minimum Current (Adjustable) | N/A | |||||||||
Maximum Current (Adjustable) | N/A | |||||||||
Current Dither Frequency | N/A | |||||||||
Dither Amplitude | N/A | |||||||||
Solenoid Selection (Nominal) | N/A | |||||||||
Dimensions | N/A | |||||||||
Analog (V or mA) | N/A | N/A | N/A | N/A | N/A 0-1V, 0-2.5V, 0-5 V, 0-10 V (2) 4-20 mA, 0-20 mA (2) | |||||
Fieldbus | N/A | N/A | N/A | N/A | N/A SAE J1939 | |||||
Proportional and On/Off Solenoid | N/A | N/A | N/A | N/A | N/A 2 (3A) | |||||
# of Connections | N/A | N/A | N/A | N/A | N/A 12 | |||||
Hazardous Locations Compliance | N/A | |||||||||
Signal Inputs | N/A | |||||||||
Digital Input | N/A | |||||||||
# Inputs | N/A | N/A | N/A | N/A | N/A 2 | |||||
RTD Inputs | N/A | |||||||||
# Outputs | N/A | N/A | N/A | N/A | N/A 2 | |||||
CAN Baud Rate | N/A | |||||||||
Memory | N/A | |||||||||
Battery Charger Mode | N/A | |||||||||
Power (Vdc) | N/A | |||||||||
Marks | N/A | N/A | N/A | N/A | N/A CE | |||||
Accessories | N/A | |||||||||
Resistive Inputs | N/A | N/A | N/A | N/A | N/A 0.020 - 250 (2) kΩ | |||||
Relay Output | N/A | |||||||||
Digital | N/A | N/A | N/A | N/A | N/A Digital (2) Frequency (2) PWM (2) RPM (2) | |||||
Strain Gauge Inputs | N/A | |||||||||
Excitation Connections | N/A | |||||||||
Connections | N/A | |||||||||
Wire Break Detection | N/A | |||||||||
Protection | N/A | N/A | N/A | N/A |
N/A
Reverse polarity protection is provided Surge protection up to 65V is provided Overvoltage shutdown of the output load is provided Undervoltage protection (hardware and software shutdown at 7.5V) is provided |
|||||
Number of Pin Plug | N/A | |||||||||
Cable Length | N/A | |||||||||
Ethernet | N/A | |||||||||
Voltage Input | N/A | |||||||||
PWM Input | N/A | |||||||||
Voltage Output | N/A | |||||||||
Output Voltage | N/A | |||||||||
Power Supply Output | N/A | |||||||||
Compliance Voltage Output | N/A | |||||||||
Adjustments Output | N/A | |||||||||
Accessories |
N/A
AX070123, Mating Plug Kit (DT06-12SA, DT06-12SB, DT06-12SC, DT06-12SD, 4 W12S-P012, 48 1462-201-16141 Contacts, 15 Sealing plugs) AX070502, Axiomatic Electronic Assistant KIT (USB-CAN Converter, USB-A to USB-B Cable, CAN Cable, Installation Instructions) |
N/A
AX070123, Mating Plug Kit (DT06-12SA, DT06-12SB, DT06-12SC, DT06-12SD, 4 W12S-P012, 48 1462-201-16141 Contacts, 15 Sealing plugs) AX070502, Axiomatic Electronic Assistant KIT (USB-CAN Converter, USB-A to USB-B Cable, CAN Cable, Installation Instructions) |
N/A
AX070123, Mating Plug Kit (DT06-12SA, DT06-12SB, DT06-12SC, DT06-12SD, 4 W12S-P012, 48 1462-201-16141 Contacts, 15 Sealing plugs) |
N/A
AX070502, Axiomatic Electronic Assistant KIT (USB-CAN Converter, USB-A to USB-B Cable, CAN Cable, Installation Instructions) PL-DTM06-12SA-12SB, Mating Plug KIT (DTM06-12SA, DTM06-12SB, 2 WM12S, 24 Contacts, Plugs) |
N/A
AX070502, Axiomatic Electronic Assistant KIT (USB-CAN Converter, USB-A to USB-B Cable, CAN Cable, Installation Instructions) PL-DTM06-12SA, Mating Plug KIT (1-12 Socket) |
|||||
Electromagnetic Compatibility (EMC) | N/A | |||||||||
Approvals | N/A | |||||||||
+V Ref | N/A | N/A | N/A | N/A | N/A 5V, 50 mA | |||||
Encoder | N/A | N/A | N/A | N/A | N/A 1 | |||||
Marine Type Approvals | N/A | |||||||||
Signal Outputs | N/A | |||||||||
Output to Motor | N/A | |||||||||
Measurement Range | N/A | |||||||||
|