The controller features 1 CAN port for controlling the outputs over the CAN bus. It accepts a nominal input power supply voltage of 12 or 24 VDC. Using the CAN network, it can provide control of up to four outputs, configured for a wide variety of responses and up to 2.5 A per channel. For example, it can drive proportional valves, on/off valves, or provide a hotshot control profile. PWM signal or proportional voltage outputs are also user-selectable. Standard control logic is provided. The sophisticated microcontroller can accommodate complex application-specific control algorithms for advanced machine control on request. Rugged enclosure and power supply surge protection suits the harsh environment of mobile equipment.
Order Code |
N/A AX020601 |
Operating Voltage |
N/A 12 or 24 VDC nominal (8 to 36 VDC) |
Outputs |
N/A
4 outputs (sourcing up to 2.5 A) selectable as: Proportional Current Output Hotshot Digital Output PWM Output Proportional Voltage Output On/Off Digital Output |
Communications |
N/A 1 CANopen® port |
Enclosure |
N/A
Molded enclosure, integral connector Nylon 6/6, 30% glass, laser welded 4.28 in x 3.69 in x 1.41 in (108.6 mm x 94 mm x 36 mm) Note: L x W x H includes the integral connector. Flammability rating: UL 94 HB |
Connections |
N/A Integral 12-pin receptacle (equivalent to TE Deutsch P/N: DTM04-12P) |
Operating Temperature |
N/A -40 to 85 ºC-40 to 185 ºF |
Applications |
N/A
The controller is designed to meet the rugged demands of mobile equipment and heavy duty industrial machine control applications, such as PID closed loop valve control and hydraulic valve control. Off-highway construction equipment and municipal vehicles |
Datasheet |
N/A
AX020601 Datasheet |
User Manual |
N/A
AX020601 User Manual |
STEP Files (3D) |
N/A
12-Pin Laser Welded Assembly |
EDS |
N/A
EDS-AX020601 |
Compliance |
N/A
LVD - DoC - All RoHS - DoC - All |