Print Back

This controller has 2 isolated CAN (SAE J1939) ports. The signal output is configurable as SINE or Square wave (0-5V). It also provides a PWM output signal. The control has a rugged IP67 enclosure and connector. To configure the device, use the Electronic Assistant.

Unit of Measure

Specifications

Order Code

N/A P/N: AX030550 (SAE J1939 250 Kbps)

Operating Voltage

N/A 12Vdc or 24Vdc nominal

Inputs

N/A 1 Universal Signal Input (Voltage, Current, Resistive, Digital, Frequency or PWM)
User selectable input range from: 0-1V; 0-2.5V; 0-5V; 0-10V; 0- 20mA; 4-20 mA; 20 Ohm to 250 kOhm (Auto Range or User Selectable Ranges); 10Hz – 1 kHz; or 100 Hz – 10 kHz

SINE or Square Wave Output

N/A 1 Signal output configurable as:
SINE wave
Square wave
Frequency is user selectable from 10 Hz to 20 kHz
Minimum load 10 kΩ
Amplitude: 5V peak-to-peak

PWM Output

N/A 1 PWM Output from 0 to 36Vps
1 Hz to 1 kHz Frequency
Current limited to 200 mA

Communications

N/A SAE J1939

Control Logic

N/A Standard embedded software is provided.
(Application-specific control logic or factory programmed setpoints are available on request.)
User programmable functionality using Electronic Assistant

Enclosure

N/A Aluminum Enclosure, Integral TE Deutsch Connector, Encapsulation
4.750 x 2.150 x 1.802 inches
120.66 x 54.61 x 45.77 mm (L X W X H)

Connections

N/A 12 pin TE IPD connector P/N: DT15-12PA

Protection Rating

N/A IP67

Operating Temperature

N/A -40 to 85 ºC-40 to 185 ºF

Reference Voltage

N/A 1 +5V +/- 0.5%, 100 mA Maximum

Applications

N/A Construction equipment trucks, interface between ECM and turbocharger.

Product Documents

Datasheet

N/A AX030550 Datasheet

User Manual

N/A AX030550 User Manual

STEP Files (3D)

N/A DT15-12PA Generic Enclosure

Compliance

N/A LVD - DoC - All
RoHS - DoC - All

Accessories

Accessories

N/A AX070105, Plug Kit (DT06-12SA, W12S, 0462-201-16141, 114017)
AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions)