This controller has 2 isolated CAN (SAE J1939) ports. The signal output is configurable as SINE or Square wave (0-5V). It also provides a PWM output signal. The control has a rugged IP67 enclosure and connector. To configure the device, use the Electronic Assistant.
Order Code |
N/A P/N: AX030550 (SAE J1939 250 Kbps) |
Operating Voltage |
N/A 12Vdc or 24Vdc nominal |
Inputs |
N/A
1 Universal Signal Input (Voltage, Current, Resistive, Digital, Frequency or PWM) User selectable input range from: 0-1V; 0-2.5V; 0-5V; 0-10V; 0- 20mA; 4-20 mA; 20 Ohm to 250 kOhm (Auto Range or User Selectable Ranges); 10Hz – 1 kHz; or 100 Hz – 10 kHz |
SINE or Square Wave Output |
N/A
1 Signal output configurable as: SINE wave Square wave Frequency is user selectable from 10 Hz to 20 kHz Minimum load 10 kΩ Amplitude: 5V peak-to-peak |
PWM Output |
N/A
1 PWM Output from 0 to 36Vps 1 Hz to 1 kHz Frequency Current limited to 200 mA |
Communications |
N/A SAE J1939 |
Control Logic |
N/A
Standard embedded software is provided. (Application-specific control logic or factory programmed setpoints are available on request.) User programmable functionality using Electronic Assistant |
Enclosure |
N/A
Aluminum Enclosure, Integral TE Deutsch Connector, Encapsulation 4.750 x 2.150 x 1.802 inches 120.66 x 54.61 x 45.77 mm (L X W X H) |
Connections |
N/A 12 pin TE IPD connector P/N: DT15-12PA |
Protection Rating |
N/A IP67 |
Operating Temperature |
N/A -40 to 85 ºC-40 to 185 ºF |
Reference Voltage |
N/A 1 +5V +/- 0.5%, 100 mA Maximum |
Applications |
N/A Construction equipment trucks, interface between ECM and turbocharger. |
Datasheet |
N/A
AX030550 Datasheet |
User Manual |
N/A
AX030550 User Manual |
STEP Files (3D) |
N/A
DT15-12PA Generic Enclosure |
Compliance |
N/A
LVD - DoC - All RoHS - DoC - All |