Print Back

The controller features four universal signal inputs configurable as Voltage, Current, Resistive, Frequency, PWM, or Digital. Depending on the model, it communicates through CAN (SAE J1939). The user can select +8V or +5V Reference. The unit is in a compact IP67 enclosure, and operates from -40°C to +85°C.

Unit of Measure

Specifications

Order Code

N/A P/N: AX030440 (SAE J1939)

Communications

N/A 1 CAN port (SAE J1939)

Control Logic

N/A Standard embedded software is provided.
(Application-specific control logic or a set point file is available on request.)

Enclosure

N/A Molded Enclosure, integral connector
Nylon 6/6, 30% Glass
Ultrasonically Welded
3.54 x 2.75 x 1.31 inches
(90.09 x 70.00 x 33.35 mm)
L x W x H including integral connector

Connections

N/A Integral TE Deutsch equivalent 12-pin receptacle (P/N: DTM04-12PA)

Protection Rating

N/A IP67

Operating Temperature

N/A -40 to 85 ºC-40 to 185 ºF

Protection

N/A Reverse polarity protection up to -100V.
Under-voltage shutdown at 5Vdc.
Over-voltage protection is up to 59 V.

Applications

N/A

Machine Automation

Inputs

N/A Four universal signal inputs configurable as:
Voltage, Current, Resistive, Frequency, PWM, or Digital

Reference Voltage

N/A +8V Reference, +5V Reference (user selectable)

Vibration

N/A MIL-STD-202G, Test 204D and 214A (Sine and Random)
10 g peak (Sine)
7.86 Grms peak (Random)

Shock

N/A MIL-STD-202G, Test 213B
50 g

Storage Temperature

N/A -55 to 125 ºC-67 to 257 ºF

Quiescent Current

N/A 55.1 mA @ 12Vdc Typical; 27.2 mA @ 24Vdc Typical

CAN Baud Rate

N/A CAN Baud Rate: 250, 500, 667 kbit/s, 1 Mbit/s. Auto-Baud-Rate Detection

Network Termination

N/A It is necessary to terminate the network with external termination resistors. The resistors are 120 Ohm, 0.25W minimum, metal film or similar type. They should be placed between CAN_H and CAN_L terminals at both ends of the network.

Enclosure (Filter)

N/A Box

Compliance

N/A CE / UKCA marking

Product Documents

Datasheet

N/A AX030440 Datasheet

User Manual

N/A AX030440 User Manual

2D Drawing

N/A AX030440-MD-A

STEP Files (3D)

N/A 12-pin US Blue Housing Assembly

Compliance

N/A EMC - DoC - AX0303XX
LVD - DoC - All
RoHS - DoC - All

Accessories

Accessories

N/A AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions)
PL-DTM06-12SA, Mating Plug KIT (1-12 Socket)