Print Back

The controller simplifies control of proportional solenoids by supplying a current proportional to an input control (0-5 VDC or 10K potentiometer or 4-20 mA). It accepts power supply voltages from 9 to 32 VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. Maximum current output is 2 Amps. The user can adjust maximum and minimum current to suit the application.

AX020100 Economy Valve Controllers, DIN Rail Mount
Unit of Measure
Items AX020100 Economy Valve Controllers, DIN Rail Mount
AX020100
RSD-LDR-SC-5V-2A 0-5Vdc Analog Input, 1 2A Output Economy Valve Controller, DIN Rail Mount
AX020100 Economy Valve Controllers, DIN Rail Mount
AX020140
RSD-LDR-SC-5V-0.3A 0-5Vdc Analog Input, 1 0.3A Output Economy Valve Controller, DIN Rail Mount
Description N/A

The controller simplifies control of proportional solenoids by supplying a current proportional to an input control (0-5 VDC or 10K potentiometer or 4-20 mA). It accepts power supply voltages from 9 to 32 VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The maximum current output is 2 A. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current to suit the application. Dither frequency and amplitude are factory set. In this economy version of the connector controller there are no ramps. The unit is installed on a DIN rail.

 

N/A

The controller simplifies control of proportional solenoids by supplying a current proportional to an input control (0-5 VDC or 10K potentiometer or 4-20 mA). It accepts power supply voltages from 9 to 32 VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The maximum current output is 300 mA. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current to suit the application. Dither frequency and amplitude are factory set. In this economy version of the connector controller there are no ramps. The unit is installed on a DIN rail.

 

Order Code N/A P/N: AX020100 N/A P/N: AX020140
Operating Voltage N/A 9 to 32VDC Nominal
Protection N/A IP20
Signal Inputs N/A 0-5 VDC voltage signal, 10K Potentiometer (accepts 5K to 50K pots), or 4-20 mA
Output Current N/A 0 to 2 A N/A 0 to 2
Enclosure N/A PA66 Nylon, Phoenix Contact P/N: UMK-SE 11
25-1-2970442 (Housing) and UMK-FE VE 500-29063654 (DIN Rail Foot)
Mounts on DIN Rail NS 32 or NS 35/7.5

Please refer to datasheet for details.
Connections N/A 2 4-pin Terminal Blocks.
Operating Temperature N/A -40 to 85 ºC-40 to 185 ºF
Applications N/A

Accurate control of hydraulic and pneumatic proportional solenoid valves used in mobile construction equipment and industrial processes.

2D Drawing N/A N/A AX020140