Print Back

The 4 Analog Signal Output CAN Controller can extend machine control networks by adding I/O to the CAN bus. Diesel engine control systems with SAE J1939 or CANopen® can communicate with 4-20 mA or other analog signal input devices using this controller as a smart interface. The Axiomatic controller can be configured to suit the specific application using a service tool. User selectable outputs include: 0-5V; 0-10V; +/-5V; +/-10V; 0-20mA; 4-20 mA; and +/-20mA. The controller comes in two models, the AX030500 for SAE J1939 networks or the AX030501 for CANopen® applications. Baud rates of up to 1 Mbit/s are available.

The controller belongs to a family of Axiomatic smart controllers with programmable internal architecture. This provides users with flexibility, allowing them to build their own custom controller with a required functionality from a set of predefined internal functional blocks using the PC-based Axiomatic Electronic Assistant software tool. Application programming is performed through the CAN interface, without disconnecting the controller from the user’s system.

AX030500 (SAE J1939/11, 250 kBit/s Baud Rate) 4 Analog Signal Outputs CAN Controller
Unit of Measure
Items AX030500 (SAE J1939/11, 250 kBit/s Baud Rate) 4 Analog Signal Outputs CAN Controller
AX030500
4 Analog Signal Outputs, SAEJ1939, 250Kbps
AX030501 (CANopen<sup>®</sup>) 4 Analog Signal Outputs CAN Controller
AX030501
4 Analog Signal Outputs, CANopen
AX030502 (SAE J1939/14 500 kbit/s Baud Rate) 4 Analog Signal Outputs CAN Controller
AX030502
4 Analog Signal Outputs, SAEJ1939, 500 kbps
AX030500 (SAE J1939/11, 250 kBit/s Baud Rate) 4 Analog Signal Outputs CAN Controller
AX030503
4 Analog Signal Outputs, SAEJ1939, 1Mbps
AX030560.jpg
AX030560
CAN, 4 Universal Outputs Controller, SAE J1939, Compact
Description N/A

The 4 Analog Signal Output CAN Controller can extend machine control networks by adding I/O to the CAN bus. Diesel engine control systems with SAE J1939 or CANopen® can communicate with 4-20 mA or other analog signal input devices using this controller as a smart interface. The Axiomatic controller can be configured to suit the specific application using a service tool. User selectable outputs include: 0-5V; 0-10V; +/-5V; +/-10V; 0-20mA; 4-20 mA; and +/-20mA. The controller comes in two models, the AX030500 for SAE J1939 networks or the AX030501 for CANopen® applications. Baud rates of up to 1 Mbit/s are available.

The controller belongs to a family of Axiomatic smart controllers with programmable internal architecture. This provides users with flexibility, allowing them to build their own custom controller with a required functionality from a set of predefined internal functional blocks using the PC-based Axiomatic Electronic Assistant software tool. Application programming is performed through the CAN interface, without disconnecting the controller from the user’s system.

N/A

The 4 Analog Signal Output CAN Controller can extend machine control networks by adding I/O to the CAN bus. Diesel engine control systems with SAE J1939 or CANopen® can communicate with 4-20 mA or other analog signal input devices using this controller as a smart interface. The Axiomatic controller can be configured to suit the specific application using a service tool. User selectable outputs include: 0-5V; 0-10V; +/-5V; +/-10V; 0-20mA; 4-20 mA; and +/-20mA. The controller comes in two models, the AX030500 for SAE J1939 networks or the AX030501 for CANopen® applications. Baud rates of up to 1 Mbit/s are available.

The controller belongs to a family of Axiomatic smart controllers with programmable internal architecture. This provides users with flexibility, allowing them to build their own custom controller with a required functionality from a set of predefined internal functional blocks using the PC-based Axiomatic Electronic Assistant® software tool. Application programming is performed through the CAN interface, without disconnecting the controller from the user’s system.

N/A

The 4 Analog Signal Output CAN Controller can extend machine control networks by adding I/O to the CAN bus. Diesel engine control systems with SAE J1939 or CANopen® can communicate with 4-20 mA or other analog signal input devices using this controller as a smart interface. The Axiomatic controller can be configured to suit the specific application using a service tool. User selectable outputs include: 0-5V; 0-10V; +/-5V; +/-10V; 0-20mA; 4-20 mA; and +/-20mA. The controller comes in two models, the AX030500 for SAE J1939 networks or the AX030501 for CANopen® applications. Baud rates of up to 1 Mbit/s are available.

The controller belongs to a family of Axiomatic smart controllers with programmable internal architecture. This provides users with flexibility, allowing them to build their own custom controller with a required functionality from a set of predefined internal functional blocks using the PC-based Axiomatic Electronic Assistant software tool. Application programming is performed through the CAN interface, without disconnecting the controller from the user’s system.

N/A

The 4 Analog Signal Output CAN Controller can extend machine control networks by adding I/O to the CAN bus. Diesel engine control systems with SAE J1939 or CANopen® can communicate with 4-20 mA or other analog signal input devices using this controller as a smart interface. The Axiomatic controller can be configured to suit the specific application using a service tool. User selectable outputs include: 0-5V; 0-10V; +/-5V; +/-10V; 0-20mA; 4-20 mA; and +/-20mA. The controller comes in two models, the AX030500 for SAE J1939 networks or the AX030501 for CANopen® applications. Baud rates of up to 1 Mbit/s are available.

The controller belongs to a family of Axiomatic smart controllers with programmable internal architecture. This provides users with flexibility, allowing them to build their own custom controller with a required functionality from a set of predefined internal functional blocks using the PC-based Axiomatic Electronic Assistant software tool. Application programming is performed through the CAN interface, without disconnecting the controller from the user’s system.

N/A

This is a versatile and compact CAN SAE J1939 controller with 4 Universal Outputs. Its hardware design allows for a wide range of output types: Analog Current, Analog Voltage, Digital PWM, Digital Frequency and Digital ON/OFF.

All logical function blocks on the unit are inherently independent from one another but can be configured to interact with each other. The control algorithms / function blocks allow the user to configure the controller for a wide range of applications without the need for custom firmware using Axiomatic Electronic Assistant.

SAE J1939 CAN network can operate at standard 250 and 500 kbit/s and non-standard 667 kbit/s and 1 Mbit/s baud rates.

The controller accepts power supply voltages from 9 to 60 Vdc.

Order Code N/A P/N: AX030500 N/A P/N: AX030501 (CANopen®) N/A P/N: AX030502 (SAE J1939/14 500 kbit/s Baud Rate) N/A P/N: AX030503 (SAE J1939 non standard, 1 Mbit/s Baud Rate) N/A P/N: AX030560
Operating Voltage N/A 12VDC, 24VDC, 48VDC Nominal (9…60VDC) N/A 12VDC, 24VDC, 48VDC Nominal (9…60VDC) N/A (12VDC, 24VDC, 48VDC Nominal) 9…60VDC N/A (12VDC, 24VDC, 48VDC Nominal) 9…60VDC N/A 12/24/24 VDC Nominal (9 to 60 VDC range)
Outputs N/A 4 independent analog signal outputs (voltage or current). User selectable output range from +/-10V or +/-20 mA, including:
0-5V; 0-10V; +/-5V; +/-10V; 0-20mA; 4-20 mA; and +/-20mA.
N/A 4 independent analog signal outputs (voltage or current). User selectable output range from +/-10V or +/-20 mA, including:
0-5V; 0-10V; +/-5V; +/-10V; 0-20mA; 4-20 mA; and +/-20mA.
N/A 4 independent analog signal outputs (voltage or current). User selectable output range from +/-10V or +/-20 mA, including:
0-5V; 0-10V; +/-5V; +/-10V; 0-20mA; 4-20 mA; and +/-20mA.
N/A 4 independent analog signal outputs (voltage or current). User selectable output range from +/-10V or +/-20 mA, including:
0-5V; 0-10V; +/-5V; +/-10V; 0-20mA; 4-20 mA; and +/-20mA.
N/A 4 signal outputs user selectable as analog current, analog voltage, digital PWM, digital frequency and digital ON/OFF
Communications N/A J1939/11, J1939/15, 250 kBit/s Baud Rate N/A CANopen®, User Selectable Baud Rate N/A J1939/14, 500 kBit/s Baud Rate N/A Non-standard SAE J1939, 1 Mbit/s Baud Rate N/A 1 CAN SAE J1939-compliant port 250 kbit/s, 500 kbit/s, 667 kbit/s, 1 Mbit/s auto-baud-rate detection
Control Logic N/A Standard Embedded Software
(For application-specific control logic, contact manufacturer.)
N/A Standard Embedded Software
(For application-specific control logic, contact manufacturer.)
N/A (For application-specific control logic, contact manufacturer.) Standard Embedded Software N/A (For application-specific control logic, contact manufacturer.) Standard Embedded Software N/A (Application-specific control logic or factory programmed setpoints are available on request.) Standard embedded control logic is provided.
User Configurability N/A Electronic Assistant, P/N: AX070502 N/A Commercially available CANopen® tools. N/A N/A N/A The controller setpoints can be viewed and programmed using the standard J1939 memory access protocol through the CAN port and the PC-based Axiomatic Electronic Assistant, AX070502 or AX070505K.
Enclosure N/A High Temperature Nylon housing
12-pin Connector
TE Deutsch PCB Enclosure (EEC-325X4B)
4.62 x 5.24 x 1.43 inches
117.42 x 133.09 x 36.36 mm
(W x L x H excluding mating plug)
N/A High Temperature Nylon housing
12-pin Connector
TE Deutsch PCB Enclosure (EEC-325X4B)
4.62 x 5.24 x 1.43 inches
117.42 x 133.09 x 36.36 mm
(W x L x H excluding mating plug)
N/A (W x L x H excluding mating plug) 117.42 x 133.09 x 36.36 mm 12-pin Connector 4.62 x 5.24 x 1.43 inches Deutsch IPD PCB Enclosure (EEC-325X4B) High Temperature Nylon housing N/A (W x L x H excluding mating plug) 117.42 x 133.09 x 36.36 mm 12-pin Connector 4.62 x 5.24 x 1.43 inches Deutsch IPD PCB Enclosure (EEC-325X4B) High Temperature Nylon housing N/A 3.55 in x 2.76 in x 1.31 in (90.1 mm x 70 mm x 33.4 mm) Molded Enclosure, integral connector Note: L x W x H excluding mating plugs Nylon 6/6, 30% glass, Ultrasonically welded
Protection Rating N/A IP67 N/A IP67 N/A IP67 N/A IP67 N/A IP67, PCB is conformal coated and protected by the housing.
Operating Temperature N/A -40 to 85 ºC-40 to 185 ºF N/A -40 to 85 ºC-40 to 185 ºF N/A -40 to 85 ºC-40 to 185 ºF N/A -40 to 85 ºC-40 to 185 ºF N/A
Applications N/A

Commercial vehicles
Off-highway Construction Equipment
Forestry Mining and Military Vehicles
Power Generation
Standby Generators
Material Handling Equipment

N/A

Commercial vehicles
Off-highway Construction Equipment
Forestry Mining and Military Vehicles
Power Generation
Standby Generators
Material Handling Equipment

N/A

Commercial Vehicles

Forestry Mining and Military Vehicles

Off-highway Construction Equipment

Standby Generators

N/A

Commercial Vehicles

Material Handling Equipment

Standby Generators

N/A

Distributed controls for power generation, co-generation, stationary power
Distributed controls for commercial vehicles, off-highway equipment, industrial equipment, etc.

Accessories N/A AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions)
PL-DTM06-12SA, Mating Plug KIT (1-12 Socket)
N/A PL-DTM06-12SA, Mating Plug KIT (1-12 Socket)
N/A AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions)
PL-DTM06-12SA, Mating Plug KIT (1-12 Socket)
N/A AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions)
PL-DTM06-12SA, Mating Plug KIT (1-12 Socket)
N/A AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions)