The Thermocouple Module monitors up to 6 channels of of type J, K, T or E thermocouples (others on request). The engine temperature information is provided to the engine control system over a SAE J1939 or CANopen bus. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All channels of temperature data are automatically sent over the CAN bus when power is applied. All channels are fully isolated and measure temperatures at the same time. The thermocouple module features rugged packaging and plug-in connections. Applications include power generator sets.
Items |
AX186000 6 Channel Thermocouple Module, 250 kbps SAE J1939 |
AX186001 6 Channel Thermocouple Module, CANopen |
AX186000-01 6 Channel Thermocouple Module, 500 kbps SAE J1939 |
AX186000-02 6 Channel Thermocouple Module,1 Mbps SAE J1939 |
||||
Description |
N/A
The Thermocouple Module monitors up to 6 channels of type J, K, T or E thermocouples (others on request). The engine temperature information is provided to the engine control system over a SAE J1939 bus. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All channels of temperature data are automatically sent over the CAN bus when power is applied. All channels are fully isolated and measure temperatures at the same time. The thermocouple module features rugged packaging and plug-in connections. Applications include power generator sets. |
N/A
The Thermocouple Module monitors up to 6 channels of of type J, K, T or E thermocouples (others on request). The engine temperature information is provided to the engine control system over a CANopen bus. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All channels of temperature data are automatically sent over the CAN bus when power is applied. All channels are fully isolated and measure temperatures at the same time. The thermocouple module features rugged packaging and plug-in connections. Applications include power generator sets. |
N/A
The Thermocouple Module monitors up to 6 channels of of type J, K, T or E thermocouples (others on request). The engine temperature information is provided to the engine control system over a SAE J1939 or CANopen bus. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All channels of temperature data are automatically sent over the CAN bus when power is applied. All channels are fully isolated and measure temperatures at the same time. The thermocouple module features rugged packaging and plug-in connections. Applications include power generator sets. |
N/A
The Thermocouple Module monitors up to 6 channels of of type J, K, T or E thermocouples (others on request). The engine temperature information is provided to the engine control system over a SAE J1939 or CANopen bus. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All channels of temperature data are automatically sent over the CAN bus when power is applied. All channels are fully isolated and measure temperatures at the same time. The thermocouple module features rugged packaging and plug-in connections. Applications include power generator sets. |
||||
Technical Specifications | N/A Thermocouple Module, 6 Channels, SAE J1939 | N/A Thermocouple Module, 6 Channels | N/A Thermocouple Module, 6 Channels, SAE J1939 | N/A Thermocouple Module, 6 Channels, SAE J1939 | ||||
Order Code | N/A P/N: AX186000 (Thermocouple Module, SAE J1939) | N/A P/N: AX186001 (Thermocouple Module, CANopen) | N/A P/N: AX186000-01 | N/A P/N: AX186000-02 | ||||
Operating Voltage | N/A 12V or 24Vdc Nominal (9...36Vdc Power Supply Range) | |||||||
Protection | N/A Reverse Polarity Protection | N/A Reverse Polarity Protection | N/A | N/A | ||||
Inputs | N/A 6 Thermocouple (TC) types J, K, B, E, N, R, S or T | |||||||
Disable Input | N/A | N/A | N/A Type J, K, B, E, N, R, S, T (6) | N/A Type J, K, B, E, N, R, S, T (6) | ||||
Communications | N/A Isolated CAN Interface SAE J1939 |
N/A
Isolated CAN Interface CANopen |
N/A Isolated CAN Interface, SAE J1939 | N/A Isolated CAN Interface, SAE J1939 | ||||
CAN Baud Rate | N/A 250 kbps | N/A | N/A 500kbps | N/A 1 Mbps | ||||
Enclosure |
N/A
High Temperature Nylon Housing, TE Deutsch PCB Enclosure (EEC-325X4B) 4.677 x 5.254 x 1.417 inches 118.80 x 133.45 x 35.99 mm (W X L X H excluding mating plug) |
N/A
High Temperature Nylon Housing, TE Deutsch PCB Enclosure (EEC-325X4B) 4.677 x 5.254 x 1.417 inches 118.80 x 133.45 x 35.99 mm (W X L X H excluding mating plug) |
N/A
High Temperature Nylon Housing TE Deutsch PCB Enclosure (EEC-325X4B) 4.677 x 5.254 x 1.417 inches (118.80 x 133.45 x 35.99 mm) W X L X H Excluding Mating Plug |
N/A
High Temperature Nylon Housing TE Deutsch PCB Enclosure (EEC-325X4B) 4.677 x 5.254 x 1.417 inches (118.80 x 133.45 x 35.99 mm) W X L X H Excluding Mating Plug |
||||
Connections |
N/A
Deutsch DTM series 24 pin receptacle (DTM13-12PA-12PB-R008). Mating Plugs Kits are Available on Request and Include Deutsch DTM06-12SA and DTM06-12SB with 2 wedgelocks (WM12S) and 24 contacts (0462-201-20141). 20 AWG wire is recommended for use with contacts 0462-201-20141. |
N/A
Deutsch DTM series 24 pin receptacle (DTM13-12PA-12PB-R008). Mating Plugs Kits are Available on Request and Include Deutsch DTM06-12SA and DTM06-12SB with 2 wedgelocks (WM12S) and 24 contacts (0462-201-20141). 20 AWG wire is recommended for use with contacts 0462-201-20141. |
N/A
Deutsch DTM series 24 pin receptacle (DTM13-12PA-12PB-R008). Mating Plugs Kits are Available on Request and Include Deutsch DTM06-12SA and DTM06-12SB with 2 wedgelocks (WM12S) and 24 contacts (0462-201-20141). 20 AWG wire is recommended for use |
N/A
Deutsch DTM series 24 pin receptacle (DTM13-12PA-12PB-R008). Mating Plugs Kits are Available on Request and Include Deutsch DTM06-12SA and DTM06-12SB with 2 wedgelocks (WM12S) and 24 contacts (0462-201-20141). 20 AWG wire is recommended for use with contacts 0462-201-20141. |
||||
Protection Rating | N/A IP67 | N/A IP67 |
N/A
IP67 Unit is Conformal Coated within the Housing |
N/A
IP67 Unit is Conformal Coated within the Housing |
||||
Applications |
N/A
Power Generator Sets |
N/A
Power Generator Sets |
N/A |
N/A
Electronic Assistant (P/N: AX070502 or AX070505K) |
||||
Accessories |
N/A
AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions) PL-DTM06-12SA-12SB, Mating Plug KIT (DTM06-12SA, DTM06-12SB, 2 WM12S, 24 Contacts, Plugs) |
N/A
PL-DTM06-12SA-12SB, Mating Plug KIT (DTM06-12SA, DTM06-12SB, 2 WM12S, 24 Contacts, Plugs) |
N/A
AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions) PL-DTM06-12SA-12SB, Mating Plug KIT (DTM06-12SA, DTM06-12SB, 2 WM12S, 24 Contacts, Plugs) |
N/A
AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions) PL-DTM06-12SA-12SB, Mating Plug KIT (DTM06-12SA, DTM06-12SB, 2 WM12S, 24 Contacts, Plugs) |
||||
|