The Thermocouple Module monitors up to 20 channels of several types of thermocouples. The engine temperature information is provided to the engine control system over a SAE J1939 or CANopen bus. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All 20 channels of temperature data are automatically sent over the CAN bus when power is applied with no additional programming or configuration required. Integral diagnostics determine thermocouple integrity and thermocouple inputs are isolated from each other. The thermocouple module features rugged packaging and watertight TE Deutsch connectors. Applications include power generator sets.
Items |
AX185000 20 Channel Thermocouple Scanner, SAE J1939 |
AX185001 20 Channel Thermocouple Scanner, CANopen |
AX185000-10 20 Channel Thermocouple Scanner, SAE J1939, CAN 2.0B |
|||
Description |
N/A
The Thermocouple Module monitors up to 20 channels of several types of thermocouples. The engine temperature information is provided to the engine control system over a SAE J1939 bus. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All 20 channels of temperature data are automatically sent over the CAN bus when power is applied with no additional programming or configuration required. Integral diagnostics determine thermocouple integrity and thermocouple inputs are isolated from each other. The thermocouple module features rugged packaging and watertight TE Deutsch connectors. Applications include power generator sets. |
N/A
The Thermocouple Module monitors up to 20 channels of several types of thermocouples. The engine temperature information is provided to the engine control system over a CAN bus. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All 20 channels of temperature data are automatically sent over the CAN bus when power is applied with no additional programming or configuration required. Integral diagnostics determine thermocouple integrity and thermocouple inputs are isolated from each other. The thermocouple module features rugged packaging and watertight TE Deutsch connectors. Applications include power generator sets. |
N/A
The Thermocouple Scanner monitors up to 20 thermocouples and provides the temperature information to the engine control system over SAE J1939 CAN 2.0B bus. The controller has 250 kbps baud-rate for the CAN communication. It interfaces with ComAp controllers (It can be used in place of the discontinued CA171000. See user manual UMAX185000-10 for details.). The input channels are independently configurable as Type J, K, B, E, N, R, S, or T thermocouples. Temperature information can include exhaust temperature and fluid temperature monitoring. All 20 channels of temperature data are automatically sent over the CAN bus when power is applied with no additional programming or configuration required. Integral diagnostics determine thermocouple integrity. All inputs are fully isolated from the CAN line, and from the power supply. During set-up, using a USB-CAN converter and a PC, the operator can configure the controller via the Axiomatic Electronic Assistant to suit a wide variety of applications. Settings are saved to non-volatile memory upon command. The Thermocouple Scanner features rugged packaging and connectors, which are TE Deutsch equivalents, for an IP67 rating. Applications include control systems for industrial and marine power generator sets (stationary or portable). |
|||
Technical Specifications | N/A Thermocouple Scanner | |||||
Order Code | N/A P/N: AX185000 | N/A P/N: AX185001 | N/A P/N: AX185000-10 | |||
Operating Voltage | N/A 9-32Vdc (12V or 24Vdc nominal) | |||||
Reverse Polarity Protection | N/A Provided | |||||
Thermocouple Inputs | N/A Reads up to 20 Type J, K, B, E, N, R, S or T thermocouple inputs | |||||
CAN | N/A SAE J1939 | N/A CANopen® | N/A CAN 2.0B SAE J1939 | |||
Enclosure |
N/A
5.86 x 5.72 x 2.87 inches 149.00 x 145.30 x 73.00 mm (W x L x H excluding mating connectors) |
|||||
Protection Rating | N/A IP67 | |||||
Compliance | N/A CE / UKCA Marking for EMC and RoHS Directives Marine Type Approvals: Lloyd’s Register TAC, CCS TAC, ABS PDA, RINA | N/A CE / UKCA Marking for EMC and RoHS Directives | N/A CE marking (EMC and RoHS Directives) | |||
Accessories |
N/A
AX070200, Plug Kit: DT06-08A, W8S, sockets + DRC16-40S (no key), sockets AX070502, Axiomatic Electronic Assistant KIT (USB-CAN Converter, USB-A to USB-B Cable, CAN Cable, Installation Instructions) |
N/A
AX070200, Plug Kit: DT06-08A, W8S, sockets + DRC16-40S (no key), sockets |
N/A
AX070200, Plug Kit: DT06-08A, W8S, sockets + DRC16-40S (no key), sockets AX070502, Axiomatic Electronic Assistant KIT (USB-CAN Converter, USB-A to USB-B Cable, CAN Cable, Installation Instructions) |
|||
Marine Type Approvals |
N/A
ABS-23-2365975-PDA ABS-23-EC5957678 BV-31048 C0 BV CCS-WG23PTB00001 DNV-TAA00001VK LR-LR23316079TA-01 RINA-ELE323823CS |
N/A | N/A | |||
|