12 digital inputs are user selectable from the following: Active High/Active Low. Features CE mark.
Items |
AX030340 1 TC, 12 Digital, 3 Universal Signal Inputs CAN Controller, SAE J1939, +5V Reference |
AX030341 1 TC, 12 Digital, 3 Universal Signal Inputs CAN Controller, CANopen, +5V Reference |
||
Technical Specifications | N/A 12 Digital Signal Inputs, 1 TC Input Controller, SAE J1939, Auto-baud-rate Detect | N/A 12 Digital Signal Inputs, 1 TC Input Controller, CANopen® | ||
Order Code | N/A P/N: AX030340 | N/A AX030341 | ||
Protection | N/A Protected against shorts to GND or +V supply. | |||
CAN | N/A 1 CAN port (SAE J1939) | N/A 1 CAN port (CANopen®) | ||
CAN Baud Rate | N/A SAE J1939, 250kbit/s, 500kbit/s, 667kbit/s, 1Mbit/s. Automatic Baud Rate Detection | N/A Selectable | ||
Protection for CAN Port | N/A Short Circuit to Ground | |||
Isolation | N/A 200Vrms Full isolation of TC input channel from the CAN line, other inputs and power supply. | |||
Network Termination | N/A 120 Ohm terminated twisted pair, baud rate up to 1Mbit/s. External 120 Ohm termination is required. | |||
Control Logic |
N/A
AX070502 Electronic Assistant KIT (includes the USB-CAN Converter, cables and EA Software. The Electronic Assistant is for Windows operating systems. It comes with a royalty-free license for use.) |
N/A EDS File | ||
Weight | N/A 0.55 (preliminary) lb0.23 (preliminary) kg | |||
Vibration |
N/A
Random Vibration: 7.65 Grms peak. Sinusoidal Component: 10 g peak. Based on MIL-STD-202G, Methods 204G and 214A. |
|||
Shock | N/A 50 g half sine pulse, 6 x 6ms per axis. Based on MIL-STD-202G, Method 213B, Test Condition A. | |||
Connections |
N/A
Deutsch DTM series 24 pin receptacle (DTM13-12PA-12PB-R008). Mating plug: Deutsch DTM06-12SA and DTM06-12SB with 2 wedgelocks (WM12S) and 24 contacts (0462-201-20141). 20 AWG wire is recommended for use with contacts 0462-201-20141. |
|||
Enclosure | N/A High Temperature Nylon housing – TE Deutsch Enclosure (EEC-325X4B) | |||
Operating Temperature | N/A -40 to 85 ºC-40 to 185 ºF | |||
Compliance |
N/A
CE Mark: EMC Directive Exempt from Low Voltage Directive RoHS Directive |
|||
Applications |
N/A
Engine controls for commercial vehicles, off-highway equipment, etc. Engine controls for power generation, co-generation, stationary power. |
N/A
Engine controls for commercial vehicles, offhighway equipment, etc. Engine controls for power generation, cogeneration, stationary power. |
||
Accessories |
N/A
AX070502, Electronic Assistant KIT (AX070501 USB-CAN, 2 Cables, Installation Instructions) PL-DTM06-12SA-12SB, Mating Plug KIT (DTM06-12SA, DTM06-12SB, 2 WM12S, 24 Contacts, Plugs) |
N/A
PL-DTM06-12SA-12SB, Mating Plug KIT (DTM06-12SA, DTM06-12SB, 2 WM12S, 24 Contacts, Plugs) |
||
|