The Economy Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (0-5 VDC or 10K potentiometer). It accepts power supply voltages from 9 to 32 VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. Maximum current output is 2 Amps (1 Amp version available). A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current to suit the application. Dither frequency and amplitude are factory set. In this economy version of the connector amplifier there are no ramps. The unit is available with a DIN 43650 connection to mount directly on the coil and comes complete with a 2 meter unterminated cable.
Items |
CAPVE-H-5V-2A-5C-2M Economy 2A Amplifier, DIN 43650A, 2m Cable |
CAPVE-H-5V-1A-5C-2M Economy 1A Amplifier, DIN 43650A, 2m Cable |
||
Description |
N/A
The Economy Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (0-5 VDC or 10K potentiometer). It accepts power supply voltages from 9 to 32 VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. Maximum current output is 2 Amps. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current to suit the application. Dither frequency and amplitude are factory set. In this economy version of the connector amplifier there are no ramps. The unit is available with a DIN 43650 connection to mount directly on the coil and comes complete with a 2 meter unterminated cable. |
N/A
The Economy Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (0-5 VDC or 10K potentiometer). It accepts power supply voltages from 9 to 32 VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. Maximum current output is 1 Amp. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current to suit the application. Dither frequency and amplitude are factory set. In this economy version of the connector amplifier there are no ramps. The unit is available with a DIN 43650 connection to mount directly on the coil and comes complete with a 2 meter unterminated cable. |
||
Technical Specifications | N/A Connector Amplifier For Proportional Valves (Economy Version), 2 Amps | N/A Connector Amplifier For Proportional Valves (Economy Version), 1 Amps | ||
Order Code | N/A P/N: CAPVE-H-5V-2A-5C-2M (2 Amp max. output - 2 m cable) | N/A P/N: CAPVE-H-5V-1A-5C-2M (1 Amp max. output - 2 m cable) | ||
Operating Voltage | N/A 9 to 32 VDC Nominal Power Supply Range | |||
Protection | N/A Reverse Polarity Protection | |||
Signal Inputs | N/A 0-5 VDC Voltage Signal or 10K Potentiometer (Accepts 5K to 50K) | |||
Input Resistance | N/A 200K Ohms | |||
Range of Maximum Output Current | N/A 2 A | N/A 1 A | ||
Response Time Output | N/A <10 mSec. (measured at 24 VDC, 5V input, solenoid inductance of <20 mH) | |||
Internal Supply for Setpoint Potentiometer | N/A +5 VDC | |||
Minimum Current (Adjustable) | N/A 0 to 500 mA (Single Turn Trim Pot) | N/A 0 to 250 mA (Single Turn Trim Pot) | ||
Maximum Current (Adjustable) | N/A 600 to 2000 mA (Single Turn Trim Pot) | N/A 300 to 1000 mA (Single Turn Trim Pot) | ||
Current Dither Frequency | N/A 90 Hz +/- 10% of Full Scale (Fixed) | |||
Dither Amplitude | N/A 5 % of Rated Maximum Current (Fixed) | |||
Solenoid Resistance Selection (Nominal) | N/A Rcoil < (Vpower supply - 1.5 V)/I-max | |||
Connections |
N/A
DIN 43650 plug 2 meters jacketed cable, 5 conductor (18 AWG). |
N/A
DIN 43650 plug. 2 meters jacketed cable, 5 conductor (18 AWG). |
||
Protection Rating | N/A IP65 when correctly installed with lid, compression washer, o-ring and base gasket. | |||
Operating Temperature | N/A 0 to 85% Relative Humidity -40 to + 85 ºC-40 to 185 ºF | |||
Approvals | N/A CE Marking | |||
Electromagnetic Compatibility (EMC) | N/A Emission EN 50081-2 Immunity EN 50082-2 | |||
Applications |
N/A
Accurate control of hydraulic and pneumatic proportional solenoid valves used in mobile construction equipment and industrial processes. |
|||
|