The 4-20mA Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (4-20mA). It accepts 12VDC or 24VDC power supply voltage. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The options for maximum current output include 2 A, 1.2 A or 600mA. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current. Ramp time, dither frequency and amplitude can also be adjusted to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. It is also available with 0-10V or 0-5V inputs. A remote mount version is housed in a rugged metal box.
Items |
AX020300 CAPV-H-4-20MA-2A-4C-2M (4-20 mA) Input, 2 A, Valve Controller with 2 m Cable |
AX020301 CAPV-H-4-20MA-1.2A-4C-2M (4-20 mA) Input, 1.2 A, Valve Controller with 2 m Cable |
AX020302 CAPV-H-4-20MA-600MA-4C-2M (4-20 mA) Input, 600 mA, Valve Controller with 2 m Cable |
AX020303 CAPV-H-4-20MA-2A-4C-5M (4-20 mA) Input, 2 A, Valve Controller with 5 m Cable |
||||
Description |
N/A
The 4-20mA Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (4-20mA). It accepts 12VDC or 24VDC power supply voltage. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The options for maximum current output include 2 A, 1.2 A or 600mA. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current. Ramp time, dither frequency and amplitude can also be adjusted to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. It is also available with 0-10V or 0-5V inputs. A remote mount version is housed in a rugged metal box. |
N/A
The 4-20mA Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (4-20mA). It accepts 12VDC or 24VDC power supply voltage. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The options for maximum current output include 2 A, 1.2 A or 600mA. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current. Ramp time, dither frequency and amplitude can also be adjusted to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. It is also available with 0-10V or 0-5V inputs. A remote mount version is housed in a rugged metal box. |
N/A
The 4-20mA Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (4-20mA). It accepts 12VDC or 24VDC power supply voltage. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The options for maximum current output include 2 A, 1.2 A or 600mA. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current. Ramp time, dither frequency and amplitude can also be adjusted to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. It is also available with 0-10V or 0-5V inputs. A remote mount version is housed in a rugged metal box. |
N/A
The 4-20mA Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (4-20mA). It accepts 12VDC or 24VDC power supply voltage. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The options for maximum current output include 2 A, 1.2 A or 600mA. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current. Ramp time, dither frequency and amplitude can also be adjusted to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. It is also available with 0-10V or 0-5V inputs. A remote mount version is housed in a rugged metal box. |
||||
Technical Specifications | N/A (4-20 mA) Input, 2 A, Valve Controller with 2 m Cable | N/A (4-20 mA) Input, 1.2 A, Valve Controller with 2 m Cable | N/A (4-20 mA) Input, 600 mA, Valve Controller with 2 m Cable | N/A (4-20 mA) Input, 2 A, Valve Controller with 5 m Cable | ||||
Order Code | N/A P/N: AX020300 | N/A P/N: AX020301 | N/A P/N: AX020302 | N/A P/N: AX020303 | ||||
Operating Voltage | N/A 12 or 24 VDC nominal | |||||||
Signal Inputs |
N/A
4-20 mA Current Signal (0-10 V and 0-5 VDC/0-20 mA/10K potentiometer control input versions are also available.) |
N/A
4-20 mA Current Signal (0-10 V and 0-5 VDC/0-20 mA/10K potentiometer control input versions are also available.) |
N/A
4-20 mA Current Signal (0-10 V and 0-5 VDC/0-20 mA/10K potentiometer control input versions are also available.) |
N/A
4-20 mA current signal (0-10 V and 0-5 VDC/0-20 mA/10K potentiometer control input versions are also available.) |
||||
Input Impedance | N/A 50 Ohms | |||||||
Range of Maximum Output Current | N/A 2A | N/A 1.2A | N/A 600mA | N/A 2A | ||||
Connections |
N/A
DIN 43650-A 2 m, 4 conductor, unterminated cable (18 AWG). (Remote mount version with cable available). |
N/A
DIN 43650-A 2 m, 4 conductor, unterminated cable (18 AWG) (Remote mount version with cable available). |
N/A
DIN 43650-A 2 m, 4 conductor, unterminated cable (18 AWG) (Remote mount version with cable available). |
N/A
DIN 43650-A 2 m, 4 conductor, unterminated cable (18 AWG) (Remote mount version with cable available) |
||||
Solenoid Resistance Selection (Nominal) | N/A Nominal Resistance of Solenoid Coil should Comply with: Rcoil < (Vpower supply - 1.5 V)/I-max | N/A Nominal Resistance of Solenoid Coil should Comply with: Rcoil < (Vpower supply - 1.5 V)/I-max | N/A Nominal Resistance of Solenoid Coil should Comply with: Rcoil < (Vpower supply - 1.5 V)/I-max | N/A Nominal resistance of solenoid coil should comply with: Rcoil < (Vpower supply - 1.5 V)/I-max. | ||||
Protection Rating | N/A IP65 when correctly installed with lid, o-ring/washer and base gasket. | N/A IP65 when correctly installed with lid, o-ring/washer and base gasket. | N/A IP65 when correctly installed with lid, o-ring/washer and base gasket. | N/A IP65 when correctly installed with lid, o-ring/washer and base gasket | ||||
Operating Temperature | N/A 40 to +85 ºC-40 to 185 ºF | N/A 40 to +85 ºC-40 to 185 ºF | N/A 40 to +85 ºC-40 to 185 ºF | N/A -40 to 85 ºC-40 to 185 ºF | ||||
Cable Length | N/A 2 m | N/A 2 m | N/A 2 m | N/A 5 m | ||||
Approvals | N/A CE Marking | |||||||
Electromagnetic Compatibility (EMC) | N/A Emission EN 50081-2 Immunity EN 50082-2 | |||||||
Applications |
N/A
Accurate control of hydraulic and pneumatic proportional solenoid valves used in mobile construction equipment and industrial processes. |
|||||||
STEP Files (3D) |
N/A
CAPVSTEP |
|||||||
|